Aller au contenu principal
Accès ouvert déclaré 2025 preprint

Automated Monitoring of Clinical Practice Guideline Adherence Using FHIR and OMOP: A Multi-Center Study in Intensive Care Units

1Citations signalées, ce qui n’est pas une note de qualité
10Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : de, ca. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Clinical practice guidelines are important tools for clinical decision support, but monitoring guideline adherence manually is highly resource-intensive. Therefore, we developed an automated system for evaluating guideline adherence based on computer-interpretable representations of guidelines. We implemented the system across multiple university hospitals and assessed its validity and performance by comparing its guideline adherence evaluations to those conducted by medical professionals. Methods We selected six representative clinical guideline recommendations from across 41 intensive care guidelines and translated these text-based recommendations into a computer-interpretable, Fast Healthcare Interoperability Resources (FHIR)-based format using an iterative consensus approach. Clinical data from five university hospitals were transformed into the Observational Medical Outcomes Partnership (OMOP) common data model. A decision support system was developed to interpret FHIR-encoded recommendations and apply them to OMOP-formatted patient data. We evaluated the system retrospectively on intensive care data covering 3.5 years and validated its performance by comparing system-generated decisions with human decisions in three hospitals. We created and iteratively refined a user interface for individual and ward-level adherence visualization. Findings We expert-reviewed more than 18,000 patient days to assess the applicability of and adherence to the recommendations. The system demonstrated 97.0% accuracy in identifying guideline applicability and adherence, with significantly higher accuracy than human reviewers (accuracy 86.6%, p<0.001, McNemar’s Test). The automated system processed more than 2000 patient days per second for a total of 2,200,000 patient days across 82,000 intensive care episodes, compared to humans’ two patient days per minute. Interpretation We demonstrate that an automated adherence monitoring system outperforms human reviewers in both accuracy and time efficiency. Using FHIR-encoded recommendations enables flexibility and scalability across hospitals with different data infrastructures. Future work should focus on integrating unstructured patient data and expanding the range of encoded recommendations. Funding Federal Ministry of Education and Research of Germany.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Automated Monitoring of Clinical Practice Guideline Adherence Using FHIR and OMOP: A Multi-Center Study in Intensive Care Units
Date Crossref
03/01/2025
Éditeur
openRxiv
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiovascular Syncope and Autonomic DisordersHeart Failure Treatment and ManagementHemodynamic Monitoring and Therapy

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.