Aller au contenu principal
Accès ouvert déclaré 2024 article

Multi-Pass Arrival Time Correction in Cyclic Ion Mobility Mass Spectrometry for Imaging and Shotgun Lipidomics

5Citations signalées — pas une note de qualité
4Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

High Resolution Image Download MS PowerPoint Slide Direct-infusion mass spectrometry (DI-MS) and mass spectrometry imaging (MSI) are powerful techniques for lipidomics research. However, annotating isomeric and isobaric lipids with these methods is challenging due to the absence of chromatographic separation. Recently, cyclic ion mobility mass spectrometry (cIM-MS) has been proposed to overcome this limitation. However, fluctuations in room conditions can affect ion mobility multipass arrival times, potentially reducing annotation confidence. In this study, we developed a multipass arrival time correction method that proved effective across various dates, room temperatures, ion mobility settings, and laboratories using mixtures of reference standards. We observed slight variations in the linear correction lines between lipid and nonlipid molecules, underscoring the importance of choosing appropriate reference molecules. Based on these results, we demonstrated that an accurate multipass arrival time database can be constructed from corrected t 0 and t p for interlaboratory use and can effectively identify isomeric lipids in MSI using only a single measurement. This approach significantly simplifies the identification process compared to determining multipass collision cross-section, which requires multiple measurements that are both sample- and time-intensive for MSI. Additionally, we validated our multipass drift time correction method in shotgun lipidomics analyses of human and mouse serum samples and observed no matrix effect for the analysis. Despite variations in dates, room temperatures, instruments, and ion mobility settings, our approach reduced the mean drift time differences from over 2% to below 0.2%.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Multi-Pass Arrival Time Correction in Cyclic Ion Mobility Mass Spectrometry for Imaging and Shotgun Lipidomics
Date Crossref
27/12/2024
Éditeur
American Chemical Society (ACS)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Mass Spectrometry Techniques and ApplicationsMetabolomics and Mass Spectrometry StudiesIon-surface interactions and analysis

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.