Aller au contenu principal
Accès ouvert déclaré 2024 article

Inflow-to-Outflow Stent Frame Expansion, Ellipticity, and Decoupling in Evolut TAVR: Implications for Mid-term Hemodynamic Performance

2Citations signalées — pas une note de qualité
14Institutions déclarées
5Pays d’affiliation déclarés

Résumé fourni par la source

Background The native aortic annulus for self-expanding transcatheter aortic valve replacement (TAVR) has variable ellipticity. A noncircular and underexpanded transcatheter aortic valve (TAV) may impact hemodynamic performance. This study aimed to quantify Evolut TAV (Medtronic) frame ellipticity and expansion 30 days post-TAVR and evaluate their impact on 1-year hypoattenuating leaflet thickening and 4-year hemodynamics. Methods We retrospectively evaluated 184 patients from the Evolut Low Risk substudy with high-quality computed tomography images. Frame ellipticity ratio and percent expansion were quantified at each frame node level 30 days after TAVR. Variables associated with frame deformation, 1-year hypoattenuating leaflet thickening, and 4-year hemodynamics were identified. Results Mean Evolut frame ellipticity was highest at the inflow (1.18 ± 0.08) and lowest at the functional leaflet region (1.05 ± 0.03) and frame outflow (1.04 ± 0.03). Frame expansion was lowest at the inflow (83.8% ± 4.9%) and highest at the functional leaflet region (97.8% ± 1.7%). TAV frame circularity and expansion significantly increased from the annular level to the leaflet region ( P < .001). Mean gradient, effective orifice area, and paravalvular regurgitation at 4 years were not affected by Evolut TAV's relative noncircularity and underexpansion at the frame inflow. Frame underexpansion at the leaflet region, however, was associated with a smaller effective orifice area at 4 years. Conclusions Evolut frame deformation at the inflow did not affect the circularity and expansion of the stent at the functional leaflet region. Mid-term (4-year) Evolut hemodynamic performance does not appear to be impacted by frame inflow geometry.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Inflow-to-Outflow Stent Frame Expansion, Ellipticity, and Decoupling in Evolut TAVR: Implications for Mid-term Hemodynamic Performance
Date Crossref
01/01/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiac Valve Diseases and TreatmentsAortic Disease and Treatment ApproachesCardiovascular Function and Risk Factors

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.