Bacterial contamination of mobile handwashing stations in hospital settings in the Democratic Republic of the Congo
Résumé fourni par la source
BACKGROUND: As part of the containment of the COVID-19 pandemic, mobile handwashing stations (mHWS) were deployed in healthcare facilities in low-resource settings. We assessed mHWS in hospitals in the Democratic Republic of the Congo for contamination with Gram-negative bacteria. METHODS: Water and soap samples of in-use mHWS in hospitals in Kinshasa and Lubumbashi were quantitatively cultured for Gram-negative bacteria which were tested for antibiotic susceptibility. Meropenem resistant isolates were assessed for carbapenemase enzymes using inhibitor-based disk and immunochromatographic tests. Mobile handwashing stations that grew Gram-negative bacteria at counts > 10,000 colony forming units/ml from water or soap were defined as highly contaminated. RESULTS: In 26 hospitals, 281 mHWS were sampled; 92.5% had the "bucket with hand-operated tap" design, 50.5% had soap available. Overall, 70.5% of mHWS grew Gram-negative bacteria; 35.2% (in 21/26 hospitals) were highly contaminated. Isolates from water samples (n = 420) comprised 50.3% Enterobacterales (Klebsiella spp., Citrobacter freundii, Enterobacter cloacae), 14.8% Pseudomonas aeruginosa and 35.0% other non-fermentative Gram-negative bacteria (NFGNB, including Chromobacterium violaceum and Acinetobacter baumannii). Isolates from soap samples (n = 56) comprised Enterobacterales (67.9%, including Pluralibacter gergoviae (n = 13)); P. aeruginosa (n = 12) and other NFGNB (n = 6). Nearly one-third (31.2%, 73/234) of Enterobacterales (water and soap isolates combined) were multi-drug resistant; 13 isolates (5.5%) were meropenem-resistant including 10 New Delhi metallo-beta-lactamase (NDM) producers. Among P. aeruginosa and the other NFGNB, 7/198 (3.5%) isolates were meropenem resistant, 2 were NDM producers. Bacteria listed as critical or high priority on the World Health Organization Bacterial Priority Pathogens List accounted for 20.3% of isolates and were present in 12.0% of all mHWS across 13/26 hospitals. Half (50.5%) of highly contaminated mHWS were used by healthcare workers and patients as well as by caretakers and visitors. CONCLUSIONS: More than one third of in-use mobile handwash stations in healthcare facilities in a low resource setting were highly contaminated with clinically relevant bacteria, part of which were multidrug resistant. The findings urge a rethink of the place of mobile handwash stations in healthcare facilities and to consider measures to prevent their contamination.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Bacterial contamination of mobile handwashing stations in hospital settings in the Democratic Republic of the Congo
- Date Crossref
- 20/12/2024
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.