Tin prefiltration in computed tomography does not significantly alter radiation-induced gene expression and DNA double-strand break formation
Résumé fourni par la source
BACKGROUND: The tin (Sn) prefilter technique is a recently introduced dose-saving technique in computed tomography (CT). This study investigates whether there is an altered molecular biological response in blood cells using the tin prefiltering technique. METHODS: Blood from 6 donors was X-irradiated ex-vivo with 20 mGy full dose (FD) protocols (Sn 150 kV, 150 kV, and 120 kV) and a tin prefiltered 16.5 mGy low dose (LD) protocol on a CT scanner. Biological changes were determined by quantification of γH2AX DNA double-strand break (DSB) foci, and differential gene expression (DGE) relative to unexposed samples were examined for seven known radiation-induced genes (FDXR, DDB2, BAX, CDKN1A, AEN, EDA2R, APOBEC3H) and 667 microRNAs (miRNA). RESULTS: EDA2R and DDB2 gene expression (GE) increased 1.7-6-fold (p = 0.0004-0.02) and average DNA DSB foci value (0.31±0.02, p<0.0001) increased significantly relative to unexposed samples, but similarly for the applied radiation protocols. FDXR upregulation (2.2-fold) was significant for FD protocols (p = 0.01-0.02) relative to unexposed samples. miRNA GE changes were not significant (p = 0.15-1.00) and DGE were similar for the examined protocols (p = 0.10-1.00). An increased frequency of lower DGE values was seen in the Sn 150 kV LD protocol compared to the 120 kV FD and Sn 150 kV FD protocols (p = 0.001-0.008). CONCLUSIONS: The current ex-vivo study indicates no changes regarding transcriptional and post-transcriptional DGE and DNA DSB induction when using the tin prefilter technique and even a significant tendency to lower radiation-induced DGE-changes due to the dose reduction of the tin prefilter with equal image quality compared to classical CT scan protocols was found.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Tin prefiltration in computed tomography does not significantly alter radiation-induced gene expression and DNA double-strand break formation
- Date Crossref
- 20/12/2024
- Éditeur
- Public Library of Science (PLoS)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.