Aller au contenu principal
Accès ouvert déclaré 2024 article

Evaluation of the validity of a perfluorooctane sulfonic acid exposure reconstruction using a measured serum concentration among workers with a wide range of exposure

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Studies among workers with a wide range of exposure to perfluoroalkyl substances inform risk assessments. Perfluorooctane sulfonate (PFOS), a ubiquitous environmental contaminant, was recently examined in relation to mortality and cancer incidence in an occupationally exposed population by Alexander et al. in 2024. In that study, cumulative occupational exposure (mg/m3 PFOS-equivalents in air) was reconstructed using a job-exposure matrix and individual work history. While the exposure reconstruction had good face validity, an assessment of its performance in relation to serum PFOS levels would allow improved interpretation of the occupational epidemiology findings. OBJECTIVE: The objective of this study was to assess the validity of the exposure reconstruction used by Alexander et al. (2024). METHODS: A previous study by Olsen et al. (2003) measured serum PFOS levels in 1998 for 260 workers and because these workers were included in the epidemiologic study by Alexander et al. (2024), the study reported herein compared serum PFOS levels to those predicted using a simple compartmental pharmacokinetic model. RESULTS: The Pearson correlation coefficient between the observed and pharmacokinetic model-predicted serum PFOS concentration was 0.80 (95% confidence interval, 0.75 to 0.84). The median ratio of predicted to observed serum concentrations was 12 (i.e. actual exposure was significantly less than predicted). The predicted serum PFOS concentrations were not sensitive to the parameters used in the pharmacokinetic model other than exposure concentration or absorption. CONCLUSIONS: The model did not predict absolute exposure well, probably because of personal protective equipment use not being accounted for and absorption of PFOS or precursors being lower than modeled. On the other hand, the model did a reasonably good job of ranking the workers' exposure, thus classification of workers according to relative amount of cumulative PFOS-equivalents was reasonably accurate in the study by Alexander et al. (2024) when validated using the measured serum PFOS data.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Evaluation of the validity of a perfluorooctane sulfonic acid exposure reconstruction using a measured serum concentration among workers with a wide range of exposure
Date Crossref
19/12/2024
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Per- and polyfluoroalkyl substances researchEffects and risks of endocrine disrupting chemicalsToxic Organic Pollutants Impact

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.