Gas leak detection by measuring dilution of ambient air with differential optical dispersion spectroscopy of oxygen
Le résumé fourni par la source
Gas leak detection is one of the most vital issues in the mining and energy industries. Despite many highly specific and sensitive laser-based spectroscopic systems available on the market, the universal optical gas leak detector is still unattainable. In this paper we demonstrate the laser gas sensing setup capable of indirect detection of virtually any gas leaks using differential optical dispersion spectroscopy of oxygen near 761 nm. A semi-fiber interferometric setup with two multi-pass gas cells yields a signal proportional to the difference in O 2 concentrations between two equal optical path length Herriott multipass cells, which is used to detect leaks of the non-absorbent nitrogen by sensing the dilution of atmospheric oxygen. This new kind of sensor could become a substantial contribution to developing gas-related industries, such as hydrogen fuel storage and transmission.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Gas leak detection by measuring dilution of ambient air with differential optical dispersion spectroscopy of oxygen
- Date Crossref
- 23/12/2024
- Éditeur
- Optica Publishing Group
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.