TEVAR versus open aortic arch replacement in ex vivo perfused human thoracic aortas
Rattachement africain : at, no. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
This study aims to assess the outcomes of therapeutic options for aortic arch pathologies by comparing thoracic endovascular aortic repair (TEVAR) with open arch replacement (OAR) using woven polyester grafts from a mechanical and biomechanical perspective, with emphasis on ex vivo perfused human thoracic aortas reproducing heart rate and stroke volume conditions. Eleven non-diseased thoracic aortas from human cadavers were divided into TEVAR (n=5) and OAR (n=6) and tested using a custom-built mock circulation loop. Pressure, diameter, and stroke volume were monitored during perfusion before and after the intervention. Samples undergoing TEVAR showed a higher ascending systolic pressure post-intervention than OAR (TEVAR: 137±9mmHg vs OAR: 126±6mmHg, p=0.017). After the intervention, a significant discrepancy in the mean pressure differences between the ascending and descending aorta ΔP was observed (TEVAR: 9±3mmHg vs OAR: 1±2mmHg, p=0.004). Input impedance at zero frequency, approximating Windkessel resistance, was higher for TEVAR than for OAR (TEVAR: 1.78±0.04 vs OAR: 1.66±0.03mmHgs/ml, p=0.004). A correlation was found between the resistance and the negative peak of the time-normalized wave intensity analysis (Kendall's coefficient τ=-0.35 and p=0.023). Another correlation was observed between resistance and ΔP (τ=0.51, p=0.001). Looking at the replication of heart rate and stroke volume over the course of the study, the observed differences can largely be attributed to the type of intervention. The results suggest that TEVAR has adverse effects compared to OAR, particularly with regard to left ventricular afterload. Clinicians should consider the possibility of increased afterload and altered wave dynamics when deciding on TEVAR, particularly in patients with pre-existing impaired cardiovascular conditions.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- TEVAR versus open aortic arch replacement in ex vivo perfused human thoracic aortas
- Date Crossref
- 01/01/2025
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Graz University of Technology Institute of Biomechanics pays non établi dans la noticeUniversité ou école supérieure
-
Medical University of Graz Diagnostic and Research Institute of Pathology pays non établi dans la noticeUniversité ou école supérieure
-
Norwegian University of Science and Technology pays non établi dans la noticeUniversité ou école supérieure
Institute of Biomechanics — Graz University of Technology, Diagnostic and Research Institute of Pathology — Medical University of Graz et Norwegian University of Science and Technology.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.