Aller au contenu principal
Accès ouvert déclaré 2024 article

Cortex kidney tissue partial oxygen pressure depends on percentage of active oxygenation during oxygenated hypothermic machine perfusion

1Citations signalées, ce qui n’est pas une note de qualité
7Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : fr, be, ch. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Preclinical and clinical studies have demonstrated the advantages of oxygenated hypothermic machine perfusion (HMPO2) during kidney preservation. However, the optimal oxygenation levels during HMPO2 remain undetermined. The aim of this study was to compare different levels of oxygenation (0%, 21%, 50%, and 100%) during 22 h of active oxygenated HMP (HMPO2) using oxygen preloading by bubbling oxygenation in the preservation solution and continuous surface oxygenation during MP in a porcine DCD model. Methods After 60 min of warm ischemia time, both kidneys of an 80 kg pig were procured and randomized to one of the following groups: (1) 22‐h static cold storage (n = 6), (2) 22‐h HMP without active oxygenation (n = 6), (3) 22‐h HMPO2 21% O2 (n = 6), (4) 22‐h HMPO2 50% O2 (n = 6), and (5) 22‐h HMPO2 100% O2 (n = 6). The primary outcome measure was to compare the different oxygen levels among the different groups assessed by cortex kidney tissue oxygen partial pressures (tpO2). Results Continuous HMPO2 resulted in a significant modification of cortex kidney tpO2. In addition, tpO2 was dependent on the percentage of oxygenation. One hundred percent oxygen resulted in a significantly higher tpO2 compared to all other study groups. In line with that, ATP resynthesis was significantly higher in the HMPO2 100% group. Conclusions This study demonstrates that continuous HMPO2 results in a significant modification of tpO2 compared with SCS, and the degree of tpO2 is positively correlated with the percentage of active oxygenation during HMP. Metabolic profile analyses (ATP resynthesis) suggest that the aerobic mechanism is better supported with higher oxygen levels (50% and 100% oxygenation).

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Cortex kidney tissue partial oxygen pressure depends on percentage of active oxygenation during oxygenated hypothermic machine perfusion
Date Crossref
06/12/2024
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Organ Transplantation Techniques and OutcomesLiver Disease and TransplantationOrgan Donation and Transplantation

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.