Study of electron tracks in Timepix3 detector at kinetic energies of 1 and 1.5 MeV

1Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

We report on measurements of 1 and 1.5 MeV monoenergetic electrons with a Timepix3-based detector using a 0.5 mm thick silicon sensor. A $^{90}$Sr $β$-emitting radioisotope was used as the source of electrons, and a monochromator equipped with an adjustable magnetic field was employed to only pass electrons of desired energy into the detector. We provide experimental results of deposited-energy spectrum in the sensor and linearity of detected tracks. Alongside with the experiment, the whole system has been modelled in software and a Monte Carlo Geant4 / Allpix$^2$ simulation of the experiment has been carried out. Generally, we find a good agreement between the two.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les sujets associés

Particle Detector Development and PerformanceNuclear Physics and ApplicationsRadiation Detection and Scintillator Technologies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.