Aller au contenu principal
Accès ouvert déclaré 2024 review

Why Portable Handheld Cardiac Ultrasound Devices Ought to Incorporate 3-lead Electrocardiographs: A Mini-narrative Review

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Introduction: Transthoracic echocardiography is a non-invasive diagnostic test used to assess the structure and function of the heart in real-time. An examination of the heart's electrical activity is done non-invasively through electrocardiography (ECG). The ECG is primarily used during an echocardiography procedure to assess the heart's rhythm and to synchronise the cardiac cycles with echocardiographic image acquisition; this enables the echocardiographer to acquire images at specific phases of the cardiac cycle. A handheld echocardiograph is not connected to the electrocardiogram, which is a clinical limitation for the point-of-care ultrasound procedure. The objectives of this review are to highlight the reasons why 3-lead electrocardiography should be incorporated into pocket-sized handheld echocardiographs to support clinicians in conducting and reporting complete cardiac investigations. Methods: An in-depth search was made on the PubMed database to find experimental and review studies that assessed the importance of 3-lead ECG in the acquisition of hand-held echocardiographic data. Four related studies were selected for this review. Results: The study found that integrating cardiac point-of-care ultrasound into primary healthcare practices such as family medicine or general practitioners’ practices and training clinicians to accurately perform the procedure can expedite cardiovascular disease diagnosis and treatment in critical and non-critical scenarios. Secondly, recent hand-held cardiac ultrasound examination outcomes are as accurate and precise as standard transthoracic echocardiography and cardiac magnetic resonance imaging. Conclusion: Furthermore, medical device companies should consider integrating and producing new hand-held echocardiographs with configured 3-lead electrocardiographs that are artificial intelligence-enhanced to assist clinicians in precise point-of-care cardiac assessments.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Why Portable Handheld Cardiac Ultrasound Devices Ought to Incorporate 3-lead Electrocardiographs: A Mini-narrative Review
Date Crossref
01/12/2024
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Ultrasound in Clinical ApplicationsUltrasound and Hyperthermia ApplicationsHemodynamic Monitoring and Therapy

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.