The implementation of speckle tracking echocardiography for cardiac resynchronization therapy optimisation. A rotational myocardial mechanics interpretation

2Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : gr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Cardiac resynchronization therapy (CRT) has an additive therapeutic influence on left ventricular function in heart failure patients, but the underlying mechanisms through which it works are not completely explained. Our aim was to further elucidate the role of this intervention via rotational mechanics using 2D speckle tracking echocardiography (2D-STE). RESULTS: We investigated 46 patients (65 ± 9 years) who received CRT. All enrolled patients were assessed on admission by 2D-STE and 6 min walk test (6 min WT) and followed in the outpatient device clinic by 2D-STE (at 1 week and 6 months post-implantation) and 6 min WT (at 6 months post-implantation). On their first appointment all biventricular systems were optimised by atrioventricular delay optimisation and by changing the temporal activation of ventricular electrodes aiming to reach the highest left ventricular effective stroke volume across all activation options. A new 2D-STE based index (twist integral) targeting to assess the rotational mechanics of the whole cardiac cycle was also measured to further explain the CRT response. Twenty-two (48%) patients were responders at 6-month follow-up and most of them had dilated cardiomyopathy. The commonest selected mode that was related with the greatest left ventricular performance response was the simultaneous activation of the 2 ventricular leads (39%). The strongest predictor of CRT response was the improvement of effective stroke volume between admission and first appointment at clinic, followed by the improvement of twist integral, the absence of coronary artery disease, and the improvement of peak systolic twist. CONCLUSIONS: Additional CRT optimisation via changing the temporal activation of ventricular electrodes is beneficial for left ventricular performance in heart failure patients. The success of biventricular pacing may also be explained by the improvement of left ventricular rotational mechanics.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
The implementation of speckle tracking echocardiography for cardiac resynchronization therapy optimisation. A rotational myocardial mechanics interpretation
Date Crossref
02/12/2024
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac pacing and defibrillation studiesCardiovascular Function and Risk FactorsMechanical Circulatory Support Devices

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.