Aller au contenu principal
Accès ouvert déclaré 2024 article

Development and application of solid phase microextraction tips (SPME LC tips) method for therapeutic drug monitoring of gefitinib by LC-MS/MS

2Citations signalées — pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

• Gefitinib it is widely used for non-small cell lung cancer treatment. • Therapeutic drug monitoring is important to optimize therapies treatments. • SPME LC tips can be applied for therapeutic drug monitoring. • The developed method was successfully applied to authentic plasma samples. • The present methodology had its green characteristic evaluated by three tools. Lung cancer can be divided into small cell lung cancer and non-small cell lung cancer (NSCLC). Among the existing therapies for NSCLC, epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKIs) can be mentioned. Gefitinib is one of the first-generation reversible EGFR-TKIs and its main metabolite is O-desmethyl-gefitinib. The therapeutic range upper limit for gefitinib has not yet been clearly established despite being an indication of its toxicity, and its adverse drug reaction may be unpredictable. Therefore, therapeutic drug monitoring (TDM) can be applied by measuring gefitinib concentration in blood and its fractions. Solid phase microextraction (SPME) is a miniaturized sample preparation technique, and SPME LC tips represent a variation of SPME. This technique utilizes an inert support coated with HPLC-type silica particles, presenting several advantages. Here, we successfully developed, optimized, and validated a green analytical method for the quantification of gefitinib and its metabolite, O-desmethylgefitinib, in plasma samples, by SPME LC tips and LC-MS/MS. Linearity was achieved from 20 to 800 ng/mL and LLOQ of 20 ng/mL. No interferences were seen at selectivity tests. Matrix effect was lower than 22.9 % and inaccuracy, intra-, and inter-run imprecision were better than 15.4 %. No carryover was observed and stability study was successfully applied for processed samples maintained in the autosampler at 10 °C for 24 h The method was applied for four authentic samples from individuals under gefitinib treatment, detecting gefitinib from 104.6 ng/mL to 777.1 ng/mL and O-desmethyl-gefitinib from 85.2 ng/mL to 499.2 ng/mL. Finally, the greenness characteristic was evaluated by three tools, achieving satisfactory results that confirm its compliance to GAC principles.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Development and application of solid phase microextraction tips (SPME LC tips) method for therapeutic drug monitoring of gefitinib by LC-MS/MS
Date Crossref
01/12/2024
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Antibiotics Pharmacokinetics and EfficacyAnalytical Methods in PharmaceuticalsHIV/AIDS drug development and treatment

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.