Aller au contenu principal
2024 conference-abstract

Abstract 4144947: Invasive Hemodynamic Validation of a Novel Echocardiographic Artificial Intelligence Screening Tool for HFpEF

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: Right heart catheterization (RHC) is the gold standard for diagnosing heart failure with preserved ejection fraction (HFpEF). An FDA-approved artificial intelligence (AI) technology uses a four-chamber transthoracic echocardiogram (TTE) image to screen patients for HFpEF. Methods: We compared invasive hemodynamic data between patients screened for HFpEF by this TTE AI algorithm. We retrospectively collected data from two cohorts of patients with an ejection fraction (EF) ≥ 50% undergoing RHC for the evaluation of HFpEF. The most recent TTE was screened using the AI tool and reported as either suggestive or non-suggestive for HFpEF – labeled as “positive” or “negative,” respectively. Invasive hemodynamic parameters at rest and during exercise were collected. Positive and negative groups were compared using Student’s t-test and Mann-Whitney U test. Results: A total of 47 patients (82% women, 79% Black, average EF 62%) had a previous RHC, with 23 undergoing subsequent exercise RHC. There were 18 patients (38%) with a positive AI result and 29 (62%) negative. Positive patients had significantly higher rates of atrial fibrillation (38% vs 11%, p=.03), NT-proBNP levels (median 451 vs 117 ug/mL, p=.001), and H2FPEF (median 6 vs 4, p<.001) and HFA-PEFF scores (median 5 vs 2, p=.005). Of 18 positive patients, 16 (89%) had a resting pulmonary capillary wedge pressure (PCWP) > 15 mmHg, consistent with HFpEF, compared to only 14 of 28 (50%) negative patients. With exercise 6 of 7 (86%) positive patients had PCWP ≥ 25 mmHg, consistent with HFpEF, compared to 11 of 20 (55%) negative patients. At rest, positive patients had significantly higher PCWP, mean pulmonary arterial pressure (mPAP), and pulmonary vascular resistance (PVR). After exercise, there were no significant differences in PCWP or mPAP between the two groups, but thermodilution cardiac output was significantly lower in the positive patients. Conclusion: Patients identified as HFpEF positive by a validated TTE-guided AI tool were more likely to have HFpEF confirmed invasively, indicating its potential for risk stratification. However, the negative predictive value for HFpEF confirmed by invasive hemodynamics was low in this population.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Abstract 4144947: Invasive Hemodynamic Validation of a Novel Echocardiographic Artificial Intelligence Screening Tool for HFpEF
Date Crossref
12/11/2024
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiovascular Function and Risk FactorsCardiac Imaging and Diagnostics

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.