Esophageal pressure as estimation of pleural pressure: a study in a model of eviscerated chest

2Citations signalées — pas une note de qualité
8Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Background Transpulmonary pressure is the effective pressure across the lung parenchyma and has been proposed as a guide for mechanical ventilation. The pleural pressure is challenging to directly measure in clinical setting and esophageal manometry using esophageal balloon catheters was suggested for estimation. However, the accuracy of using esophageal pressure to estimate pleural pressure is debated due to variability in the mechanical properties of respiratory system, esophagus and esophageal catheter. Furthermore, while a vertical pleural pressure gradient exists across lung regions, esophageal pressure balloon provides a single value, representing, at most, the pressure surrounding the esophagus. Methods In a swine model with a preserved esophagus and a single homogenous, easily measurable intrathoracic pressure, we evaluated esophageal pressure’s agreement with intrathoracic pressure at different positive end-expiratory pressure (PEEP) levels (0, 5, 10, 15 cmH2O). We assessed the improvement of measurement accuracy by correcting absolute esophageal values using a previously described technique, that accounts for the pressure generated by the esophageal wall in response to esophageal balloon inflation. The study involved five swine, wherein two different esophageal catheters were used alongside the four distinct PEEP levels. Swings, uncorrected and corrected absolute esophageal pressures (end-inspiratory, end-expiratory) were compared with their respective intrathoracic pressures. The effect of correction technique was assessed with manual incremental step inflation procedure. Results We found that both catheters significantly overestimated absolute esophageal pressure compared to intrathoracic pressure (5.01 ± 3.32 and 6.06 ± 5.62 cmH2O at end-expiration and end-inspiration, respectively), with error increasing at higher positive end-expiratory pressure levels (end-expiration: 2.36 ± 2.03, 3.77 ± 1.37, 6.24 ± 2.51 and 7.69 ± 4.02 for each PEEP level, P < 0.0001; end-inspiration: 1.71 ± 2.10, 3.70 ± 1.73, 7.67 ± 3.62 and 11.14 ± 7.60 for each PEEP level, P = 0.0004). Applying the correction technique significantly improved agreement for absolute values (0.82 ± 1.62 and 1.86 ± 3.94 cmH2O at end-expiration and end-inspiration, respectively). Esophageal pressure swings accurately estimated intrathoracic pressure swings at low-medium intrathoracic pressures (-0.64 ± 0.62, -0.07 ± 0.53, 1.43 ± 1.51, and 3.45 ± 3.94 at PEEP 0, 5, 10 and 15 cmH2O, respectively; P = 0.0197). Conclusions The correction technique, based on the mechanical response of esophageal wall to the balloon inflation, is fundamental for obtaining reliable estimations of absolute intrathoracic pressure values, and for ensuring its correct application in clinical setting.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Esophageal pressure as estimation of pleural pressure: a study in a model of eviscerated chest
Date Crossref
14/11/2024
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Respiratory Support and MechanismsPleural and Pulmonary DiseasesChronic Obstructive Pulmonary Disease (COPD) Research

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.