Aller au contenu principal
Accès ouvert déclaré 2024 conference-abstract

SURG-57. FLUORESCENCE LIFETIME IMAGING (FLIM) PROVIDES HIGHLY ACCURATE, DYE-FREE TUMOR MARGIN DETECTION DURING GLIOMA RESECTIONS

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract INTRODUCTION Fluorescence guided tumor margin detection is an important tool to enhance the extent of resection for gliomas. Existing dyes, such as 5-ALA, require planned administration, surgical resection in dark conditions, and are only effective for high-grade tumors. We have developed a novel laser scanning probe to assess tissue autofluorescence decay (lifetime) which allows tumor margin detection without exogenous dyes and under normal room light conditions. This technology has been optimized for margin detection in low-grade and high-grade gliomas. METHODS Patients undergoing craniotomy for resection of gliomas were enrolled. During resection of the final tumor margin, multiple 1x1 mm regions were scanned with FLIm and biopsied for evaluation by a neuropathologist. FLIm data and ground truth pathology were processed by a machine-learning algorithm to develop classifiers for the FLIm data. Classifiers were then applied to the full data set to determine the accuracy of FLIm predictions. RESULTS 12 patients with non-enhancing (LGG) and 25 patients with enhancing (HGG) tumors were enrolled, with a total of 228 biopsies obtained. For LGG, sensitivity of FLIm for detection of residual tumor was 0.89 (95% CI 0.8-0.98) with a specificity of 0.92 (95% CI 0.86-0.97), resulting in a positive predictive value of 0.76 and negative predictive value of 0.96 with an overall accuracy of 0.91. For HGG, sensitivity of FLIm for detection of residual tumor was 0.92 (95% CI 0.84-1.0) with a specificity of 0.95 (95% CI 0.91-0.99), resulting in a positive predictive value of 0.90 and negative predictive value of 0.96 with an overall accuracy of 0.94, exceeding reported values for 5-ALA. CONCLUSION FLIm can distinguish between residual low and high-grade glioma and normal brain at resection margins with very high sensitivity and specificity. This quantitative technology does not require administration of exogenous dyes and can be used under normal room light illumination.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
SURG-57. FLUORESCENCE LIFETIME IMAGING (FLIM) PROVIDES HIGHLY ACCURATE, DYE-FREE TUMOR MARGIN DETECTION DURING GLIOMA RESECTIONS
Date Crossref
01/11/2024
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Glioma Diagnosis and TreatmentNanoplatforms for cancer theranostics

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.