Aller au contenu principal
2024 conference-abstract

A newly-developed negative pressure ventilation (NPV) applied to patients with chronic obstructive pulmonary disease (COPD)

0Citations signalées — pas une note de qualité
5Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Using NPV adjuvant with pulmonary rehabilitation may unload ventilatory muscles, and decrease ventilation/perfusion mismatch, reduce breathing work and dyspnea, leading to a decrease in exacerbations and mortality in COPD. However, the cuirass of the available NPV machine may not fit the body shape of our patients resulting in less negative pressure suction. We developed an improved new design ergonomic negative pressure ventilator for COPD in co-operation with Industrial Technology Research Institute and JooGood Inc. in Taiwan. First, we developed a new patented cuirass together with a newly-developed negative pressure ventilator. 28 COPD patients randomly used either the available NPV (n=13) or the new NPV (n=15) for 3 months. Total lung capacity (TLC), residual volume (RV), RV/TLC and 6 min walk test (6MWT) were performed before and after the treatment. Our newly-developed cuirass was more comfortable, adherent to body, and more easy operation, lightness, and satisfaction than the available NPV. After 3-month treatment, our newly developed NPV effectively reduced RV and the ratio of RV/TLC, while the available NPV didnot show any effect. The 6 min walk distance was significantly increased from 366.1±36.6 M to 413.5±28.5 M (p<0.05). Our new NPV improved oxygen saturation (86.9±1.8% vs 89.4±1.3%, p<0.05) and dyspnea sensation (Borg scale 5.5±0.6 vs 4.1±0.4, p<0.05) after 6MWT in COPD patients after 3-month treatment. The available NPV had no positive effect. Our newly-developed NPV and cuirass provided more ergonomic and comfortable treatment, while providing improvement in exercise tolerance, exercise-induced oxygen desaturation and dyspnea in COPD patients.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A newly-developed negative pressure ventilation (NPV) applied to patients with chronic obstructive pulmonary disease (COPD)
Date Crossref
14/09/2024
Éditeur
European Respiratory Society
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Respiratory Support and MechanismsChronic Obstructive Pulmonary Disease (COPD) Research

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.