Aller au contenu principal
2024 conference-abstract

P253 Association between a computed cardiopulmonography (CCP) ventilation-inhomogeneity index and conventional markers of small-airway function

0Citations signalées — pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Introduction Small airway dysfunction has gained increasing attention for its critical role in pathophysiological changes associated with chronic airway disease. Computed cardiopulmonography (CCP) is novel physiological technique: A bespoke molecular flow sensor measures accurate, highly-time-resolved respired gas composition and flow-rate data during a multiple breath washout test.2 These data enable the determination of patient-specific parameters describing respiratory physiology using a computational lung model. One such parameters, σlnCL, is a sensitive index of ventilation inhomogeneity that reflects the variability in lung inflation/deflation (alveolar compliance) across the lung. We hypothesise that σlnCL is a sensitive parameter indicating small-airway dysfunction. Aim To assess the association between σlnCL and conventional markers of small-airway dysfunction obtained using impulse oscillometry (Tremoflo) and spirometry. Method Forty asthmatic patients participated in this cross-sectional study. The average age was 56 ±15 years (mean ± S.D.) and 22(55%) were male. Patients had varying disease severity: 13(33%) patients were at GINA steps I-III, 18(45%) were at GINA IV-V (not on biologics) and 9 (22%) at GINA V on biologics. Patients were assessed using spirometry, oscillometry and CCP. Forced expiratory flow (FEF) 25–75 % predicted and R5–20 Z score were considered conventional assessments of small airway function. Spearman correlation was used to evaluate associations between each of these parameters and σlnCL. Results Figure 1 demonstrates our results. σlnCL is significantly correlated with both FEF25–75 % predicted (r = -0.52, p=0.0006) and R5–20 Z score (r = 0.63, p<0.0001). Conclusion The significant correlation between σlnCL and parameters of small airway dysfunction reveals its potential as a sensitive measure of physiological changes in the smaller airways in asthma. References DOI: 10.1152/japplphysiol.00745.2017. DOI: 10.1126/sciadv.1600560.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
P253 Association between a computed cardiopulmonography (CCP) ventilation-inhomogeneity index and conventional markers of small-airway function
Date Crossref
01/11/2024
Éditeur
BMJ Publishing Group Ltd and British Thoracic Society
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Respiratory Support and Mechanisms

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.