Reliability, concurrent validity and clinical feasibility of measurement methods determining local tissue water in patients with lower limb lymphedema and healthy controls
Rattachement africain : us, be, nl, gb. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Purpose To investigate reliability, concurrent validity and clinical feasibility of local tissue water measurements in patients with lower limb lymphedema and healthy controls.Methods In this cross-sectional study the Moisture Meter D Compact device® (MMDC) measurement and “pitting test” were performed three times by two assessors to test intra- and inter-rater reliability in 47 patients and 30 healthy controls. To investigate the between-session reliability, 29 patients and 21 healthy controls were reassessed two weeks later. Time efficiency and practical limitations were evaluated. The concurrent validity was investigated between the two tests. Clinical trial registration number: NCT:05269264.Results Of the MMDC values, 58% showed strong to very strong intra-rater reliability, 32% showed strong to very strong inter-rater reliability and 36% had strong to very strong between-session reliability. Absolute values had generally a higher reliability than inter-limb or leg-to-arm ratio values. The pitting test had nil to perfect agreement between assessments (Cohen’s kappa = −0.03–1.00) with fewer practical limitations and shorter performance time than the MMDC. Between both tests nil to a moderate relationship was found (Kendall’s tau c = 0.00–0.60).Conclusion The MMDC and pitting test are reliable and feasible measurements to assess local tissue water depending on the location, but should not be used interchangeably.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Reliability, concurrent validity and clinical feasibility of measurement methods determining local tissue water in patients with lower limb lymphedema and healthy controls
- Date Crossref
- 29/10/2024
- Éditeur
- Informa UK Limited
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.