Aller au contenu principal
Accès ouvert déclaré 2024 article

Prevalence, determinants, and impact of significant shunt after percutaneous patent foramen ovale closure

0Citations signalées — pas une note de qualité
13Institutions déclarées
4Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Introduction Percutaneous closure of patent foramen ovale closure is increasingly performed for secondary prevention of PFO-related arterial embolic event. The clinical significance of postclosure residual right-to-left significant shunt remains unclear. Purpose To describe the prevalence, determinants, and clinical impact of a significant post-closure. Methods The AIR-FORCE is an ongoing prospective international registry of patients undergoing PFO closure from 19 centers in France, Canada and Italy. Only patients undergoing PFO for secondary prevention of an arterial embolic event with at least one available post-closure contrast transthoracic echocardiography (TTE) with agitated saline injection and Valsalva maneuvers were analyzed. Residual shunt was categorized according to the number of bubbles in the left atrial within 3 cardiac cycles at the first available contrast TTE as small (<10), moderate (10-20) or severe (> 20). Determinants of the presence of moderate or severe shunt were evaluated with multivariate logistic regression and its impact on the primary outcome (stroke, transient ischemic attack or peripheral arterial emboly) was evaluated with Cox model adjusted on age and sex. Results A total of 2413 patients, with a median age of 49.3 [40.4-57.4] years, 56% male, undergoing PFO closure between 2001 and 2023 were included. The first contrast TTE, which was performed after a median delay of 3.4 [0.9-5.8] months, reported the presence of moderate or severe residual shunt in 214 (8.9% 95%CI 7.8-10.1) patients. Determinants of the presence of moderate or severe residual shunt at the first contrast TTE were decreased body mass index (per 1kg/m², aOR 0.96 95%CI 0.93-0.99), severe shunt prior to PFO closure (aOR 3.54 95%CI 2.25-5.55) and increased device left disc diameter (per 1mm, aOR 1.08 95%CI 1.05-1.12). With a median follow-up of 2.2 [0.9-4.9] years, a total of 60 events were reported and the presence of moderate or severe residual shunt was associated with an increased risk of the primary outcome (aHR 2.46 95%CI 1.15-5.24) (Figure 1). Conclusions A moderate to severe residual right-to-left intracardiac shunt is not uncommon after PFO percutaneous closure and seems to be associated with an increased risk of arterial emboly recurrence.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Prevalence, determinants, and impact of significant shunt after percutaneous patent foramen ovale closure
Date Crossref
01/10/2024
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiovascular and Diving-Related ComplicationsTraumatic Brain Injury and Neurovascular DisturbancesCerebrospinal fluid and hydrocephalus

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.