Aller au contenu principal
Accès ouvert déclaré 2024 article

Comparison of DNA extraction procedures for detection of Mycoplasma bovis directly from extended bovine semen straw samples using a commercial M. bovis PCR

2Citations signalées — pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Background Mycoplasma bovis is a global pathogen of cattle but was detected for the first time in New Zealand in 2017, triggering a response under their Biosecurity Act as an “unwanted organism”. Following a lengthy eradication campaign, the Ministry of Primary Industries (MPI) now requires all bovine semen destined for export to New Zealand to be screened with an M. bovis-specific real-time PCR (rtPCR) compliant with amended import health standard (IHS) test requirements aimed at preventing the accidental importation of M. bovis. The standard stipulates that semen samples cannot be centrifuged prior to DNA extraction. To comply with these strict requirements, one of the listed tests was validated together with different DNA preparation steps and compared with existing in-house procedures. DNA was extracted from semen straws using the current in-house semi-automated platform procedures for processing culture, tissue and body fluid sample submissions and was compared with the stipulated test requirements. DNA from centrifuged and unspun semen samples spiked with M. bovis was also compared. Results The rtPCR had a sensitivity and specificity of 100% (95% confidence interval = 79–100% and 74–100%, respectively) when testing DNA from other Mycoplasma species or bovine semen spiked with the latter, with a high level of repeatability for within- and between- run replicates. The consistent limit of detection was 0.001 pg/µl M. bovis DNA and between 5.3 × 102 and 7.5 × 102 CFU/ml M. bovis when artificially spiked in semen. DNA extracted using the KingFisher Flex was detected with lower Cq values than the Maxwell 16, but the comparable improvements in sensitivity were mainly associated with non-centrifuged samples (p < 0.001). None of the procedures tested impeded the detection sensitivity of M. bovis in the presence of competitor organisms Acholeplasma laidlawii, Mycoplasma bovigenitalium and Ureaplasma diversum, confirming M. bovis specificity of the polC target. Conclusions Under the experimental conditions applied, this rtPCR test efficiently detected M. bovis in extended bovine semen straw samples from DNA extracted using both semi-automated extraction platforms, irrespective of prior centrifugation of extended semen.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparison of DNA extraction procedures for detection of Mycoplasma bovis directly from extended bovine semen straw samples using a commercial M. bovis PCR
Date Crossref
26/10/2024
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Microbial infections and disease researchAnimal Virus Infections StudiesAnimal Disease Management and Epidemiology

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.