Regulatory Testing of RPP-WTP HLW Glasses to Support Delisting Compliance, VSL-04R4780-1, Rev. 0 (Sep 2004)
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
The primary goal of the testing described in this report was to collect data to demonstrate compliance of the immobilized high-level waste (IHLW) glasses with delisting requirements. The collected data will be used to support a petition to delist the IHLW glasses destined for the national disposal facility. The Delisting Data Quality Objectives (DQO) (Cook and Blumenkranz 2003) identified a list of (16) inorganic constituents of potential concern (COPCs) and their associated limits for delisting. These COPCs can be divided into three groups, Cases 1, 2, and 3, based on their Toxicity Characteristic Leaching Procedure (TCLP) responses versus their respective delisting limits. To briefly summarize, Case 1 COPCs are those that, when loaded at their highest expected concentration in Waste Treatment Plant (WTP) glasses, are not expected to leach at their respective delisting limits when the glasses are exposed to the TCLP. Case 2 COPCs may reach the delisting limits in TCLP leachates of WTP glasses if loaded to concentrations near their maximum expected concentrations in glass. Finally, Case 3 COPCs are components that are likely to be present in concentrations sufficient to exceed their respective delisting limits in TCLP leachates of some possible glasses. The test objective was to show that, for (i) the expected range of inorganic contents in the waste feed to the Hanford WTP high level waste (HLW) vitrification facility, (ii) the expected range of glass product compositions, and (iii) the Case 1 and Case 2 COPCs identified by the DQO, the IHLW glasses meet all the relevant requirements for delisting. For Case 3 COPCs (i.e., Cd), the testing was to demonstrate the relationship between glass composition and TCLP cadmium (Cd) release, and then employ the results to develop TCLP-composition response models. During WTP operations, TCLP-composition models can be used to predict, within the required statistical uncertainties, TCLP responses of IHLW production glasses that are within the compositional region used to develop the model.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Regulatory Testing of RPP-WTP HLW Glasses to Support Delisting Compliance, VSL-04R4780-1, Rev. 0 (Sep 2004)
- Date Crossref
- 01/09/2024
- Éditeur
- Office of Scientific and Technical Information (OSTI)
- Type
- report
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of America pays non établi dans la noticeUniversité ou école supérieure
-
Catholic University of America pays non établi dans la noticeUniversité ou école supérieure
-
Battelle pays non établi dans la noticeOrganisation à but non lucratif
-
Pacific Northwest National Laboratory pays non établi dans la noticeStructure de recherche
-
The Catholic Univ. of America pays non établi dans la noticeInstitution
University of America, Catholic University of America et Battelle, avec 2 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.