Aller au contenu principal
Accès ouvert déclaré 2024 article

Accuracy of estimating equations for the assessment of glomerular filtration rate in critically ill patients versus outpatients

4Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : se. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Estimating equations for the assessment of glomerular filtration rate (GFR) have been poorly investigated in the critical care setting. We evaluated the agreement between the GFR measured with 51 CrEDTA/iohexol (mGFR) and four estimating equations based on serum concentrations of creatine and/or cystatin C (eGFR) in two cohorts: critically ill patients and outpatients with normal‐to‐moderately reduced GFR. Methods Forty‐three patients in the critical care group and 48 patients in the outpatient group were included. GFR was measured (mGFR) by plasma infusion clearance of 51 Cr‐EDTA/iohexol (critical care group) and the single injection, one‐sample plasma 51 Cr‐EDTA clearance technique (outpatients). The following estimating equations (eGFR) were used: the Chronic Kidney Disease Epidemiology Collaboration (CKD‐EPI) equation for creatinine (CKD‐EPI Cr ), cystatin C (CKD‐EPI Cys C ), creatinine+cystatin C (CKD‐EPI Cr + Cys C ) and the Lund‐Malmö creatinine+cystatin C equation (LM Cr + Cys C ). Agreement between mGFR and eGFR was assessed by the Bland–Altman method and accuracy by calculating P30 and P10. Results In the critically ill group, the bias between the estimating equations and mGFR was −3.6 to 2.8 mL/min/1.73 m 2 , while the error was 121%–127% and the accuracy (P30) 33%–40%. In the outpatients, the bias between the estimating equations and mGFR was −13.0 to 7.6 mL/min/1.73 m 2 , while the error was 31%–41% and the accuracy (P30), 67%–96%. Conclusions All four equations performed poorly in assessing GFR in the critically ill cohort with an unacceptably high error and low accuracy in contrast to the outpatient group. To accurately assess GFR in critically ill patients, GFR must be measured not estimated. Editorial Comment For the assessment of glomerular filtration rate (GFR), it can be measured directly, but is frequently estimated using a point measure of serum creatinine concentration. In this study, ICU case GFR estimations, by different adjusted equations, done also for a cohort of outpatients, showed that these serum creatinine‐based estimations for ICU cases are not highly precise or reliable.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Accuracy of estimating equations for the assessment of glomerular filtration rate in critically ill patients versus outpatients
Date Crossref
22/10/2024
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Chronic Kidney Disease and DiabetesAcute Kidney Injury ResearchDialysis and Renal Disease Management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.