Aller au contenu principal
Accès ouvert déclaré 2024 article

Influence of Anesthesiology Protocol on the Quality of Intraoperative Nerve Monitoring During Thyroid Surgery, One-Year Single Center Experience

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : rs. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background/Objectives: Anesthesia plays a very important role in the successful management of intraoperative neuromonitoring (IONM). The aim of our study was to investigate the impact of anesthesia induction and maintenance on the quality of signals during surgeries on the thyroid and parathyroid glands using neuromonitoring. Methods: The study included 72 patients who underwent surgery with IONM for one year. All the patients were intubated using a Glidescope videolaryngoscope with a hyperangulated blade. Two different approaches were used to facilitate intubation: succinylcholine-1 mg/kg and rocuronium bromide-0.3 mg/kg. For anesthesia maintenance, total intravenous anesthesia (TIVA) or combined anesthesia was used. Patients’ body movements during operations, as well as electromyography signals from the vagus and recurrent laryngeal nerves before resection, were recorded as V1 and R1. Results: Intraoperative unwanted movements were recorded in 25% of patients. Undesired movements were more frequently recorded in the TIVA group compared to the combined anesthesia group (p < 0.001) as well as in patients who received succinylcholine compared to patients who received rocuronium bromide (p = 0.028). Type of anesthesia maintenance as well as type of muscle relaxant did not affect the quality of recorded nerve signals. (p = 0.169 and p = 0.894, respectively). Conclusions: The type of muscle relaxant used significantly affects the occurrence of undesirable movements during thyroid surgery with IONM, while the type of anesthesia maintenance did not influence either the quality of the obtained signal or the occurrence of undesirable movements.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Influence of Anesthesiology Protocol on the Quality of Intraoperative Nerve Monitoring During Thyroid Surgery, One-Year Single Center Experience
Date Crossref
22/10/2024
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Thyroid and Parathyroid SurgeryAirway Management and Intubation TechniquesIntraoperative Neuromonitoring and Anesthetic Effects

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.