Aller au contenu principal
2024 conference-abstract

Abstract P129: Assessing the impact of serum lead levels on kidney function Among hypertensive population: NHANES 2017-2020

1Citations signalées — pas une note de qualité
6Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Purpose: Hypertension and chronic kidney disease is known adverse effects of lead poisoning. However, there is limited evidence on the magnitude of the relationship between blood lead levels and kidney function, especially on a national scale. This study investigates the association of serum lead levels (Pb-S) with estimated glomerular filtration rate (eGFR). Method: A national study of 6,789 adults, using NHANES 2017-2020 data, analyzed the correlation between Pb-S and eGFR. Participants were categorized into non-hypertension and hypertension groups based on self-reported for doctor diagnosis, with three linear regression models employed. Results: In our population, 35.6% have been diagnosed with hypertension, with 36.1% in males and 35.2% in females. The average SBP and DBP were 130.7 ± 17.8 mmHg and 77.6 ± 12.7 mmHg, respectively. The average Pb-S level was 1.04 ± 0.68 µg/dL, with 1.16 ± 0.72 µg/dL for males and 0.94 ± 0.63 µg/dL for females (mean difference 0.22 ± 0.02, P<0.001). Individuals with hypertension had higher mean Pb-S levels compared to those without hypertension (1.15 ± 0.70 vs. 0.98 ± 0.66 µg/dL; mean difference 0.17 ± 0.02, P<0.001). In the final adjusted model, eGFR declined by -1.28 (95% CI: -2.16 to -0.39) in the total group, by -0.35 (95% CI: -1.50 to 0.80) in the non-hypertension group, and by -2.50 (95% CI: -3.90 to -1.11) in the hypertension group, respectively (Fig 1). Conclusion: The Pb-S is inversely associated with kidney function in adult hypertensive population in the United States Testing for Pb-S may be considered to especially in hypertensive patients with declined kidney function who are at risk for lead exposure or toxicity.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Abstract P129: Assessing the impact of serum lead levels on kidney function Among hypertensive population: NHANES 2017-2020
Date Crossref
01/09/2024
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Heavy Metal Exposure and Toxicity

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.