Abstract P437: Correlation between plasma CT-proET-1 and renal dysfunction in patients with resistant hypertension. A biomarker analysis of the PRECISION study.
Rattachement africain : ch. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Hypothesis: Endothelin (ET)-1 is upregulated in hypertension and especially resistant forms of hypertension. As ET-1 is a paracrine hormone involved in renal organ damage, we investigated the correlation between eGFR and activity of the ET system in the resistant hypertensive population of the PRECISION trial (NCT03541174), in which aprocitentan, a dual endothelin ETA/ETB receptor antagonist, significantly reduced blood pressure and UACR. To assess activity of the ET system, ET-1 and CT-proET-1, a stable peptide and biomarker for ET-1 production, were measured in plasma. Methods: From plasma collected at screening from the future randomized patients in PRECISION, ET-1 (n=688) and CT-proET-1 (n=100, randomly selected) were measured by ELISA and LC-MS-based assays respectively. Baseline levels of CT-proET-1 were determined on pooled plasma from healthy adults (n=70). Pearson correlation coefficient was determined between biomarkers of the ET system and eGFR. Results: CT-proET-1 concentrations measured in patients with resistant hypertension were higher than concentrations from healthy subjects (83 vs 55 pM). In patients with an eGFR≥60 mL/min/1.73m2, mean CT-proET-1 concentration was 75 pM [95% CI 70-81; n=77] as compared to 116 pM [95% CI 95-140 n=23] in patients with eGFR<60 mL/min/1.73m2. In these two subgroups, mean ET-1 concentrations were 1.90 ng/L [95% CI 1.85-1.95; n=531] and 2.10 ng/L [95% CI 1.99-2.22; n=157] for patients with an eGFR≥60 and eGFR<60 mL/min/1.73m2 respectively. There was an inverse correlation between CT-proET-1 and eGFR (r=-0.61, p<0.0001) and a less pronounced correlation between ET-1 and eGFR (r=-0.11, p=0.0027) (see Figure). Conclusions: In patients with resistant hypertension, there was a strong inverse correlation between plasma CT-proET-1 and renal function, suggesting the role of the ET system not only in hypertension but also in renal damage. These data demonstrate that CT-proET-1 is a sensitive biomarker of the ET system, reflecting the production of ET-1.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Abstract P437: Correlation between plasma CT-proET-1 and renal dysfunction in patients with resistant hypertension. A biomarker analysis of the PRECISION study.
- Date Crossref
- 01/09/2024
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.