AIMS: Integrating remote monitoring (RM) into existing healthcare practice for heart failure (HF) patients to improve clinical outcome remains challenging. The ECOST-CRT study compared the clinical outcome of a comprehensive RM scheme including a patient questionnaire capturing signs and symptoms of HF and notifications for HF specific parameters to traditional RM in patients with cardiac resynchronization therapy (CRT) devices. METHODS AND RESULTS: Patients were randomized 1:1 to standard daily RM (notification for technical parameters and ventricular arrhythmias; control group) or comprehensive RM (adding a monthly symptom questionnaire and notifications for biventricular pacing, premature ventricular contraction, atrial arrhythmias; active group). The primary endpoint was all-cause mortality or hospitalization for worsening HF (WHF). Six hundred fifty-two patients (70.4 ± 10.3 years, 73% men, left ventricular ejection fraction 29.1 ± 7.6%, 68% CRT-Defibrillators, 32% CRT-Pacemakers) were enrolled. The COVID-19 pandemic caused an early termination of the study, so the mean follow-up duration was 18 ± 8 months. No statistically significant difference in the primary endpoint was found between the groups [59 (18.3%) control vs. 77 (23.3%) active group; log-rank test P = 0.13]. Among the secondary endpoints, the MLHF questionnaire showed a larger share of patients with improvement of quality of life compared to baseline in the active group (78%) vs. control (61%; P = 0.03). CONCLUSION: The study does not support the notion that comprehensive RM, when compared to standard RM, in HF patients with CRT improves the clinical outcome of all-cause mortality or WHF hospitalizations. However, this study was underpowered due to an early termination and further trials are required. REGISTRATION: Clinical Trials.gov Identifier: NCT03012490.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comprehensive vs. standard remote monitoring of cardiac resynchronization devices in heart failure patients: results of the ECOST-CRT study
Date Crossref
01/10/2024
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac pacing and defibrillation studiesHeart Failure Treatment and ManagementCardiovascular and exercise physiology

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.