Comprehensive vs. standard remote monitoring of cardiac resynchronization devices in heart failure patients: results of the ECOST-CRT study
Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
AIMS: Integrating remote monitoring (RM) into existing healthcare practice for heart failure (HF) patients to improve clinical outcome remains challenging. The ECOST-CRT study compared the clinical outcome of a comprehensive RM scheme including a patient questionnaire capturing signs and symptoms of HF and notifications for HF specific parameters to traditional RM in patients with cardiac resynchronization therapy (CRT) devices. METHODS AND RESULTS: Patients were randomized 1:1 to standard daily RM (notification for technical parameters and ventricular arrhythmias; control group) or comprehensive RM (adding a monthly symptom questionnaire and notifications for biventricular pacing, premature ventricular contraction, atrial arrhythmias; active group). The primary endpoint was all-cause mortality or hospitalization for worsening HF (WHF). Six hundred fifty-two patients (70.4 ± 10.3 years, 73% men, left ventricular ejection fraction 29.1 ± 7.6%, 68% CRT-Defibrillators, 32% CRT-Pacemakers) were enrolled. The COVID-19 pandemic caused an early termination of the study, so the mean follow-up duration was 18 ± 8 months. No statistically significant difference in the primary endpoint was found between the groups [59 (18.3%) control vs. 77 (23.3%) active group; log-rank test P = 0.13]. Among the secondary endpoints, the MLHF questionnaire showed a larger share of patients with improvement of quality of life compared to baseline in the active group (78%) vs. control (61%; P = 0.03). CONCLUSION: The study does not support the notion that comprehensive RM, when compared to standard RM, in HF patients with CRT improves the clinical outcome of all-cause mortality or WHF hospitalizations. However, this study was underpowered due to an early termination and further trials are required. REGISTRATION: Clinical Trials.gov Identifier: NCT03012490.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Comprehensive vs. standard remote monitoring of cardiac resynchronization devices in heart failure patients: results of the ECOST-CRT study
- Date Crossref
- 01/10/2024
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.