Aller au contenu principal
Accès ouvert déclaré 2024 article

Evaluation navigation controlled gate of aging spillway on cavitation damage

5Citations signalées — pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: High-speed flow of clean water or water with sediment released from aging spillways may cause abrasion and cavitation on the concrete surface gradually. The occurrence of irregularities on the concrete surface can exacerbate the erosion problem. Which might jeopardize the safety of dams constantly, hence the rehabilitation efforts become urgent tasks in dam safety projects. METHODS: This study employs a 3D Computational Fluid Dynamics (CFD) model to quantitatively analyze the cavitation risk on the aging concrete surface of the Chay 5 spillway in Ha Giang, Vietnam, under various operation scenarios. There are two standards used to measure cavitation: the cavitation index (σ) which indicates the danger due to the drop of pressure in rapid flow, and the new gasification index (β) which takes into consideration the formation and collapse of bubbles behind asperities. RESULTS: Three extreme flood cases may not result in potential cavitation because both σ and β exceed critical thresholds. Regarding the six controlled gate scenarios with normal water level, the σ profiles are approximated 1,0 showing a low likelihood of cavitation damage while the β values are smaller than 0.8, indicating a considerable risk of cavitation. Besides, the opening height of 100 cm poses the greatest risk of creating severe cavitation erosion in the concave area and slope portion. The flip bucket experienced the most vulnerable cavitation when the opening height is 400 cm. In addition, an approach to spillway surface rehabilitation involving specialized mortars has been presented. CONCLUSION: For aging conveyance structure, gasification index (β) takes into account irregularities surface, providing a more comprehensive assessment of the likelihood of cavitation damage than cavitation index (σ). After rehabilitation with anti-shrinkage high abrasion resistance mortar, the entire spillway surface is smooth. This allows for reducing the cavitation risk and improvement of life service thereof.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Evaluation navigation controlled gate of aging spillway on cavitation damage
Date Crossref
09/10/2024
Éditeur
Public Library of Science (PLoS)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Hydraulic flow and structuresDam Engineering and SafetyHydrology and Sediment Transport Processes

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.