Aller au contenu principal
2024 article

Combining capillary electrophoresis and chemometric tools for the straightforward determination of imidazolinone herbicides in plant‐based milks

0Citations signalées — pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Abstract BACKGROUND Highly polar herbicides, such as imidazolinones, are used for weed control to increase agricultural productivity and crop quality. However, their misapplication can lead to residues in ready‐to‐eat food with a potential health risk for consumers. Hence, the fast determination of these herbicides is necessary for timely action. In this work, an eco‐friendly method based on capillary zone electrophoresis combined with chemometrics was used for the determination of imazapyr and imazamox in vegetable‐based beverages such as soy and quinoa milk. RESULTS The analytical strategy consisted of only three steps: (i) protein precipitation prior to sample injection (ii) data pre‐processing to reduce the background and make corrections on electrophoretic times shift, and (iii) resolution of fully overlapped capillary electrophoresis (CE) peaks by the well‐known partial least square (PLS) algorithm, which extracts quantitative information attributed to the analytes. The method was successfully applied in the concentration range between 1.00 and 100 μg L−1 with coefficient of determination of the calibration (R2cal) and prediction (R2pred) > 0.90, residual prediction deviation of calibration (RPDcal) and of prediction (RPDpred) > 3, and relative error of prediction (REP) > 11 in the analyzed sample matrices, in the three built methods (quinoa samples, soy samples, and joint quinoa and soy samples). CONCLUSION The proposed methodology offers a simple and quick alternative for determining imidazolinones at trace concentrations in vegetable beverages, such as quinoa and soy milk, without complex sample preparation. The results were consistent with those obtained using more complex techniques, confirming the applicability of this method. © 2024 Society of Chemical Industry.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Combining capillary electrophoresis and chemometric tools for the straightforward determination of imidazolinone herbicides in plant‐based milks
Date Crossref
07/10/2024
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Analytical chemistry methods developmentPesticide Residue Analysis and SafetyElectrochemical sensors and biosensors

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.