Endo-Aortic Clamping with the IntraClude® Device in Minimally Invasive Total Coronary Revascularization via Left Anterior Thoracotomy (TCRAT)
Rattachement africain : de, ro. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Minimally invasive, sternum-sparing total coronary revascularization in multivessel disease via left anterior mini-thoracotomy (TCRAT) was introduced recently. Intra-aortic balloon occlusion is a conceivable option to avoid manipulation of the ascending aorta, to reduce the risk of stroke and to be able to treat patients with severe calcifications and unfavorable aortic anatomies. Background/Objectives: The aim of our study was to show that the use of the IntraClude® device, as part of minimally invasive coronary artery bypass grafting (CABG) via left anterior mini-thoracotomy, is feasible. Methods: From May to December 2023, CABG via left anterior mini-thoracotomy on cardiopulmonary bypass and cardioplegic arrest was successfully performed in 20 patients (17 male, 67.6 ± 8.2 (51–82) years). All patients had significant coronary artery disease (three-vessel: n = 6; two-vessel: n = 11; one-vessel: n = 3) with indication for surgical revascularization. The mean EuroScore2 was 2.6. Results: All patients successfully underwent minimally invasive CABG using endo-aortic balloon occlusion. A total of 43 distal anastomoses (2.2 ± 0.6 (1–3) per patient) were performed by using left internal artery mammary (n = 20) and radial artery (n = 14) for grafting the left anterior descending (n = 19), circumflex (n = 15) and right (n = 6) coronary artery. There was no hospital mortality, no stroke, no myocardial infarction or repeat revascularization. A total of 15 out of 20 patients left hospital within 8 days after surgery. Conclusions: TCRAT by using the IntraClude® device is feasible without compromising surgical principles while avoiding the external manipulation of the ascending aorta. The use of intra-aortic balloon occlusion instead of transthoracic clamps further reduces the invasiveness of the procedure.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Endo-Aortic Clamping with the IntraClude® Device in Minimally Invasive Total Coronary Revascularization via Left Anterior Thoracotomy (TCRAT)
- Date Crossref
- 02/10/2024
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.