BACKGROUND: End-stage heart failure is associated with high mortality. Recent developments such as the left ventricular assist device (LVAD) have improved patient outcomes. The HeartMate 3 LVAD is a novel centrifugal pump that was developed to provide hemodynamic support in heart failure patients, either as a bridge-to-transplant (BTT), myocardial recovery, or destination therapy (DT). Our objective was to evaluate the survival rates and LVAD-related complications of the HeartMate 3 LVAD before and after hospital discharge in our center. METHODS: We retrospectively reviewed all patients implanted with the HeartMate 3 LVAD in our institute between September 2015 and June 2024. Patients who received a Heart Ware Ventricular Assist Device (HVAD) and HeartMate 2 LVAD devices were excluded. The primary endpoint was survival before and after hospital discharge. The secondary endpoints included an incidence of serious LVAD adverse events (bleeding, major infection, hemolysis, device thrombosis and malfunction, and neurological dysfunction) and the causes of re-admission along the follow-up period. RESULTS: A total of 48 consecutive HeartMate 3 LVAD patients were enrolled in this study. The mean age was 56.1 ± 10.6 years. A total of 72.9% of patients received LVAD therapy as a BTT, 14.6% as DT, 10.4% as a bridge-to-decision, and 2.1% as a bridge-to-recovery. A total of 85.4% of patients were discharged after implantation. The main cause for in-hospital mortality was right ventricular failure (8.3%), followed by stroke, abdominal bleeding, and multi-organ failure (2.1% each). One patient (2.1%) had successful heart transplantation, 26 patients (63.4%) are still on LVAD support, and 11 (26.8%) patients have died during follow-up. The main cause of mortality after hospital discharge was sepsis, which occurred in 9.8% of patients, followed by right ventricular failure, non-LVAD-related causes, unknown causes with two (4.9%) cases each, and one case of fatal stroke (2.4%). During the follow-up, there was no need for LVAD replacement. CONCLUSIONS: HeartMate 3 LVAD is associated with excellent in-hospital survival rates in patients with end-stage heart failure. Right ventricular failure was the main cause of death before hospital discharge, whereas sepsis was the main cause of death after hospital discharge.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Nine Years of Continuous Flow LVAD (HeartMate 3): Survival and LVAD-Related Complications before and after Hospital Discharge
Date Crossref
30/09/2024
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Mechanical Circulatory Support DevicesTransplantation: Methods and OutcomesCardiac Structural Anomalies and Repair

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.