Aller au contenu principal
Accès ouvert déclaré 2024 article

Comparison of single shot and multishot diffusion-weighted imaging in 5-T magnetic resonance imaging for brain disease diagnosis

3Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: Diffusion-weighted imaging (DWI) with single-shot echo-planar imaging (ssEPI) is a valuable tool for detecting acute brain lesions but does suffer from image distortions. Multishot echo-planar imaging (msEPI) is a technique for reducing such distortions. This study aimed to compare the image quality and diagnostic efficacy of ssEPI- and msEPI-DWI at 5.0 T for brain disease detection. Methods: This study retrospectively reviewed images of 107 consecutive patients with suspected brain diseases who underwent ssEPI- and msEPI-DWI at 5.0 T at the First Affiliated Hospital of University of Science and Technology of China from August 2023 to September 2023. Two radiologists independently graded image quality and measured the image distortion. Signal-to-noise ratio, contrast-to-noise ratio, and apparent diffusion coefficient (ADC) were calculated and compared between ssEPI- and msEPI-DWI. Image quality scores were compared using the Wilcoxon test and other continuous variables by the paired t-test. The diagnostic accuracy of ADC values in distinguishing lesions from normal-appearing tissues was measured with the area under the curve (AUC). Results: Image quality evaluation and distortion analysis revealed that msEPI-DWI significantly outperformed ssEPI-DWI (two-sided P<0.001). No significant difference was observed in signal-to-noise ratio, contrast-to-noise ratio, or ADC values between msEPI- and ssEPI-DWI (two-sided P≥0.601). The ADC values of msEPI- and ssEPI-DWI showed strong correlations for both lesions (r=0.97) and contralateral normal tissues (r=0.91) (two-sided P<0.001). Compared to those of the contralateral white matter, ADC values of low-grade gliomas (LGGs) were significantly higher [ssEPI-DWI: 1,119.9±273.1 vs. 805.1±73.9; msEPI-DWI: 1,196.2±355.6 vs. 757.3±98.0 (unit: ×10−6 mm2/s)], while the ADC values of acute cerebral infarction (ACI) lesions were significantly lower [ssEPI-DWI: 603.9±273.2 vs. 888.9±212.0; msEPI-DWI: 538.0±281.2 vs. 905.0±188.9 (unit: ×10−6 mm2/s)] (two-sided P≤0.003). The AUCs for detecting LGGs were excellent for both ssEPI-DWI [AUC =0.934; 95% confidence interval (CI): 0.84–1.00] and msEPI-DWI (AUC =0.944; 95% CI: 0.86–1.00) (two-sided P<0.001; two-sided DeLong test: P=0.833). Conclusions: As compared to ssEPI-DWI, msEPI-DWI, when performed at 5.0 T, demonstrated superior image quality and less anatomical distortion in a wide spectrum of brain diseases and showed promising diagnostic performance for LGGs and ACI. In the future, msEPI-DWI at 5.0 T could become clinically routine in the diagnosis and grading of brain disorders.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparison of single shot and multishot diffusion-weighted imaging in 5-T magnetic resonance imaging for brain disease diagnosis
Date Crossref
01/10/2024
Éditeur
AME Publishing Company
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced Neuroimaging Techniques and ApplicationsMRI in cancer diagnosisAdvanced MRI Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.