Aller au contenu principal
2024 conference-paper

Quantifying Uncertainty in SPECT Imaging Using a Gamma Statistical Model with Spatial Covariance

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : ca. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PurposeUncertainty assessment improves radiopharmaceutical dosing accuracy, aiding clinicians in predicting therapeutic outcomes and minimizing side effects. It ensures that scanner performance aligns with design specifications through routine quality checks on sensitivity, bias, and 3-D capabilities. Building on research that normalized PET data with the Gamma model, we aim to extend this method to SPECT, analyzing statistical distributions and spatial covariance in reconstructed images to refine noise recalibration and enhance uncertainty estimates.MethodsThe method involves two main steps: data analysis within the ROI and simulated data generation. Initially, voxel-level shape and scale parameters in the ROI are estimated through multiple scans or by re-binning List-mode data from a single scan to adjust for changes due to radioactive decay and biological clearance. We used 5 images to normalize data and construct a spatial autoregressive matrix, which scales simulated Gaussian white noise accordingly. The white-noise variance equals the mean voxel value, consistent with Poisson distribution. These images help calculate the ROI’s relative error, defined as the standard deviation divided by the mean value. Validation involves using the XCAT phantom and SIMIND software to simulate a patient scenario with a liver tumor post 6.85 GBq 177Lu-DOTATATE injection. OSEM reconstructions are performed with 10 to 30 iterations across 6 subsets.Results and DiscussionThe covariance from 600 noise realization images guided the selection of a 5-order neighbor model for the spatial autoregressive matrix, optimizing accuracy and simplicity. Results showed symmetric covariance, allowing us to limit optimization to 5 coefficients and speed up computations. This model application significantly reduced autocorrelation and showed that relative error in total counts across the ROI or tumor area increases with the number of OSEM reconstruction iterations.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Quantifying Uncertainty in SPECT Imaging Using a Gamma Statistical Model with Spatial Covariance
Date Crossref
26/10/2024
Éditeur
IEEE
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Statistical Methods and InferenceStatistical Methods in Clinical TrialsHealth Systems, Economic Evaluations, Quality of Life

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.