Wall conditions in WEST during operations with a new ITER grade, actively cooled divertor
Rattachement africain : fr, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
• The standard WEST wall conditioning sequence was successful in enabling the phase II of plasma operations with a now entire, actively cooled, ITER grade, lower divertor. • Glow discharge boronization at both operation and bake temperature reduced the radiated power fraction significantly, with longer lasting effects for the latter case. • We measure a slow but sure increase of radiated power fraction after 28 GJ and ∼3h of repetitive 1-minute-long plasma pulses far from any glow discharge boronization. Future fusion reactors like ITER and DEMO will have all-tungsten (W) walls and long pulses. These features will make wall conditioning more difficult than in most of the existing devices. The W Environment Steady-state Tokamak (WEST) is one of the few long pulse (364 s) fusion devices with actively cooled W plasma-facing components in the world. WEST is a unique test bed to study impurity migration and plasma density control via reactor relevant wall conditioning techniques. The phase II of WEST operations began in 2022, after the installation of a new lower divertor, now entirely equipped with actively cooled, ITER grade, W monoblocks. After pump down, we baked WEST between 90 °C and 170 °C for ∼2 weeks. After 82.5 h at 90 °C and 33 h at 170 °C, vacuum conditions were stable with a vessel pressure of 6x10 -5 Pa and mass spectra dominated by H 2 molecules. While at 170 °C, we performed ∼40 h of D 2 glow discharge cleaning (GDC) and ∼5 h of glow discharge boronization (GDB), using a 15 %-85 % B 2 D 6 -He mix and a total boron mass of ∼12 g. This was the very first GDB at such high temperature for WEST. The whole wall conditioning sequence led to a ∼10 times reduction of the H 2 O signal as well as to a ∼3 times reduction of the O 2 signal, according to mass spectra. Once back to 70 °C, the vessel pressure was 5.5x10 -6 Pa and plasma restart was seamless with ∼30 s cumulated over the very first 5 pulses and an Ohmic radiated power fraction F rad = 0.6, showing successful conditioning of the new ITER grade divertor. The effect of the first, ‘hot’ GDB faded with a characteristic cumulative injected energy of 2.45 GJ and saturation towards F rad ∼0.8. After 1.4 h and 7.5 GJ of cumulative plasma time and injected energy, we carried out a second GDB, this time at 70 °C. This ‘cold’ GDB initially led to a much lower Ohmic F rad = 0.3–0.4 but the effect lasted ∼7 times less, with a characteristic cumulative injected energy of 0.37 GJ. At the end of the campaign, we cumulated ∼3h and ∼30 GJ through repetitive, minute long pulses without any boronization. Throughout this 4-weeks-long experiment, F rad in the 4 MW heating phase evolved only marginally (from 0.5 to 0.55). This increase is mostly due to the build-up of re/co-deposited layers on both lower divertor targets.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Wall conditions in WEST during operations with a new ITER grade, actively cooled divertor
- Date Crossref
- 01/12/2024
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.