Long guidewire peripheral intravenous catheters in emergency departments for management of difficult intravenous access: A multicenter, pragmatic, randomized controlled trial
Rattachement africain : au. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: A quarter of patients who present to emergency departments (EDs) have difficult intravenous access (DIVA), making it challenging for clinicians to successfully place a peripheral intravenous catheter (PIVC). Some literature suggests that guidewire PIVC improves first-insertion success rate. AIM: The aim was to determine the clinical and cost-effectiveness of a novel long PIVC (5.8 cm) with a retractable coiled guidewire (GW-PIVC) for patients with DIVA, compared with standard care PIVCs. METHODS: A pragmatic randomized controlled trial was conducted in two Australian EDs. Eligible participants were adults assessed as meeting DIVA criteria. Participants were randomized (1:1 ratio; stratified by hospital) to either GW-PIVC (long) or standard care group (short or long PIVC). The use of ultrasound was discretionary in the standard care group and was recommended in the GW-PIVC group due to the pragmatic design that was primarily testing the GW-PIVC rather than the ultrasound use. Primary outcome was first-insertion success and secondary outcomes included all-cause device failure, patient and staff satisfaction, and cost-effectiveness. The analysis was intention to treat. RESULTS: A total of 446 participants were randomized and 409 received PIVCs. The use of GW-PIVC, compared with standard PIVC, had a lower first-insertion success rate (68% vs. 77%, odds ratio [OR] 0.65, 95% confidence interval [CI] 0.43-0.99, p < 0.05). There was no difference in PIVC failure (134.0 per 1000 catheter days [GW-PIVC] vs. 111.8 [standard PIVC] per 1000 catheter days, hazard ratio 1.18, 95% CI 0.72-1.95). Both participant (8/10 vs. 9/10, median difference [MD] -1.00, 95% CI -1.37 to -0.63) and clinician (8/10 vs. 10/10, MD -2.00, 95% CI -2.37 to -1.63) satisfaction was lower with GW-PIVCs compared with standard PIVCs. More nurses inserted standard PIVCs than GW-PIVCs (56.9% vs. 36.5%) and had less confidence in their ultrasound skills (28.0% vs. 46.6% self-claimed as advanced/expert users). The cost per participant of GW-PIVC insertions was 2.46 times greater than standard PIVC insertions ($AU80.24 vs. $AU32.57). CONCLUSIONS: GW-PIVCs had significantly lower first-insertion success and non-significantly higher all-cause catheter failure. Additional training and device design familiar to clinicians are vital factors to enhance the likelihood of successful future implementation of GW-PIVCs.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Long guidewire peripheral intravenous catheters in emergency departments for management of difficult intravenous access: A multicenter, pragmatic, randomized controlled trial
- Date Crossref
- 09/09/2024
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.