Artificial intelligence-generated targets and inter-observer variation in online adaptive radiotherapy of bladder cancer
Résumé fourni par la source
Background and purpose Daily target re-delineation in online adaptive radiotherapy (oART) introduces uncertainty. The aim of this study was to evaluate artificial intelligence (AI) generated contours and inter-observer target variation among radiotherapy technicians in cone-beam CT (CBCT) guided oART of bladder cancer. Materials and methods For each of 10 consecutive patients treated with oART for bladder cancer, one CBCT was randomly selected and retrospectively included. The bladder (CTV-T) was AI-segmented (CTV-T AI ). Seven radiotherapy technicians independently reviewed and edited CTV-T AI , generating CTV-T ADP . Contours were benchmarked against a ground truth contour (CTV-T GT ) delineated blindly from scratch. CTV-T ADP and CTV-T AI were compared to CTV-T GT using volume, dice similarity coefficient, and bidirectional local distance. Dose coverage (D 99% >95 %) of CTV-T GT was evaluated for treatment plans optimized for CTV-T AI and CTV-T ADP with clinical margins. Inter-observer variation among CTV-T ADP was assessed using coefficient of variation and generalized conformity index. Results CTV-T GT ranged from 48.7 cm 3 to 211.6 cm 3 . The median [range] volume difference was 4.5 [−17.8, 42.4] cm 3 for CTV-T ADP and −15.5 [−54.2, 4.3] cm 3 for CTV-T AI , compared to CTV-T GT . Corresponding dice similarity coefficients were 0.87 [0.71, 0.95] and 0.84 [0.64, 0.95]. CTV-T GT was adequately covered in 68/70 plans optimized on CTV-T ADP and in 6/10 plans optimized on CTV-T AI with clinical margins. The median [range] coefficient of variation was 0.08 [0.05, 0.11] and generalized conformity index was 0.78 [0.71, 0.88] among CTV-T ADP . Conclusions Target re-delineation in CBCT-guided oART of bladder cancer demonstrated non-isotropic inter-observer variation. Manual adjustment of AI-generated contours was necessary to cover ground truth targets.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Artificial intelligence-generated targets and inter-observer variation in online adaptive radiotherapy of bladder cancer
- Date Crossref
- 01/07/2024
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.