Aller au contenu principal
Accès ouvert déclaré 2024 article

Evaluation of 68Ga-FAPI PET/CT and 18F-FDG PET/CT for the diagnosis of recurrent colorectal cancers

14Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Objective The present study aimed to compare the diagnostic value of gallium-68-labeled fibroblast activation protein inhibitor positron emission tomography/computed tomography ( 68 Ga-FAPI PET/CT) and fluorine-18-labeled fluorodeoxyglucose PET/CT ( 18 F-FDG PET/CT) for detecting recurrent colorectal cancers (CRCs). Materials and Methods Fifty-six patients (age: 18–80 years, 31 men and 25 women) with suspected recurrent CRC were enrolled and underwent 18 F-FDG PET/CT and 68 Ga-FAPI PET/CT sequentially within 1 week. The maximum standard uptake value (SUVmax), tumor-to-background ratio (TBR), and diagnostic accuracy were estimated and compared between the two modalities by using Student's t -test. The Wilcoxon signed-rank test was used to compare peritoneal carcinoma index (PCI) scores between the two imaging modalities. Results 68 Ga-FAPI PET/CT showed higher sensitivity for detecting recurrence (93 % vs. 79 %); lymph node metastasis (89 % vs. 78 %), particularly peritoneal lymph node metastasis (92 % vs. 63 %); and metastatic implantation on the intestinal wall (100 % vs. 25 %) compared to 18 F-FDG PET/CT. However, 68 Ga-FAPI PET/CT showed lower sensitivity for detecting bone metastasis (67 % vs. 100 %). The mean SUVmax values of peritoneal metastases and metastatic implantation on the intestinal wall were 4.28 ± 2.70 and 7.58 ± 1.66 for 18 F-FDG PET/CT and 5.66 ± 1.97 and 6.70 ± 0.25 for 68 Ga-FAPI PET/CT, respectively. Furthermore, 68 Ga-FAPI PET/CT showed significantly higher TBR for peritoneal metastatic lesions (4.22 ± 1.47 vs. 1.41 ± 0.89, p < 0.0001) and metastatic implantation on the intestinal wall (5.63 ± 1.24 vs. 2.20 ± 0.5, p = 0.02) compared to 18 F-FDG PET/CT. For the same patient, 68 Ga-FAPI PET/CT yielded a more accurate PCI score and a greater area under the curve value for the receiver operating characteristic curve (p < 0.01) than 18 F-FDG PET/CT. Conclusion 68 Ga-FAPI PET/CT was superior to 18 F-FDG PET/CT for detecting recurrence and peritoneal metastases. Hence, we propose the combination of these two modalities for better clinical diagnosis and management of patients with CRC.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Evaluation of 68Ga-FAPI PET/CT and 18F-FDG PET/CT for the diagnosis of recurrent colorectal cancers
Date Crossref
01/11/2024
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Peptidase Inhibition and AnalysisProtease and Inhibitor MechanismsRadiopharmaceutical Chemistry and Applications

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.