Analysis of adenoma detection rate of colonoscopy among trainees
Rattachement africain : kr. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
PURPOSE: To analyze adenoma detection rate (ADR) and related quality indicators of colonoscopy among trainees and make recommendations for appropriate colonoscopy training. METHODS: ADR and related indicators of colonoscopies performed by 3 trainees and 5 colonoscopy experts between March and November 2022 were analyzed. These indicators were analyzed in both the entire patients and the screening/surveillance group. In addition, the training period of the 3 trainees was divided into 3 sections, and the changes in these indicators were examined. RESULTS: The mean ADR of the 3 trainees was 50.6%. In the screening/surveillance group, the mean ADR of the 3 trainees was 51.8%, showing no significant difference from the experts' ADR (53.4%). When the training period was divided into 3 sections and analyzed in the screening/surveillance group, the mean ADR of the trainees gradually increased to 49.4%, 52.6%, and 53.6%, respectively; however, the difference was insignificant. Analyzing each trainee's ADR, there was a significant difference among the 3 trainees (58.5% vs. 44.7% vs. 50.2%, P=0.008). However, in the third section of the training period, the 3 trainees' ADRs were 53.0%, 49.2%, and 57.3%, respectively, showing no significant difference (P=0.606). CONCLUSION: In the early stages of training, the ADR was higher than recommended; however, there were variances in ADR between individuals. As the training period passed, the ADR became similar at the expert level, whereas the difference in ADR between trainees decreased. Therefore, efforts to increase ADR should be made actively from the beginning of training and continued during the training period.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Analysis of adenoma detection rate of colonoscopy among trainees
- Date Crossref
- 31/12/2024
- Éditeur
- Korean Society of Coloproctology
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.