Automatic identification of ablation targets in persistent atrial fibrillation: Initial experience with a new mapping tool
Rattachement africain : mc, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
INTRODUCTION: Strategies beyond pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) are debated. A novel mapping tool provides algorithmic detection of ablation targets based on electrogram (EGM) properties specific to stable localized rotational activations. METHODS: The mapping tool was used on 31 patients (20 de novo). The algorithm was used to optimize PVI line placement and guide additional ablations. Targets were detected by calculating local cycle length (L-CL) and local spread of activation within that L-CL (Duty Cycle; DC) for EGMs with consistent morphology and activation. At least two left atrial (LA) maps (pre-PVI and post-PVI) were acquired in atrial fibrillation (AF) in all patients (except those with AF termination during PVI). Extra-pulmonary vein (PV) targets were compared between the two LA maps in each patient. Follow-up included Holter monitoring every 3 months. RESULTS: Patients had a median of 3 extra-PV drivers/targets. The majority (81%) were localized in the same areas between the two LA maps. All patients had progressive AF organization demonstrated by global activation slowing: histogram peak L-CL increased from 162 to 171 ms (post-PVI; p = .0003) than to 175 ms (posttarget ablation; p = .04). Moreover, L-CL dispersion was reduced by ablation; in 50% their values tended to cluster around two dominant cycles. In de novo patients AF terminated to sinus rhythm or atrial tachycardia (AT) within 48 h postprocedure in 88% of cases, and at 18 months mean follow-up recurrence occurred in only five (25%) patients (three persAF, two AT). There were no complications. CONCLUSION: The algorithmic detection of EGMs consistent with localized reentry during sequential mapping of persAF provided reproducible targets for ablation. This allowed personalized PVI and limited, highly-selective, extra-PV ablation. Results of this initial experience included progressive organization of AF with ablation and a low recurrence rate after a single procedure.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Automatic identification of ablation targets in persistent atrial fibrillation: Initial experience with a new mapping tool
- Date Crossref
- 19/08/2024
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Princess Grace Hospital Centre pays non établi dans la noticeÉtablissement de santé
-
Boston Scientific (United States) pays non établi dans la noticeEntreprise
-
Cambridge Scientific (United States) pays non établi dans la noticeEntreprise
-
Departement of Cardiology Centre Hospitalier Princesse Grace Monaco Monaco Departement of Cardiology pays non établi dans la noticeÉtablissement de santé
-
University of Medicine and Pharmacy Timişoara Timișoara Romania pays non établi dans la noticeUniversité ou école supérieure
-
Boston Scientific Corp. Cambridge Massachusetts USA pays non établi dans la noticeInstitution
Princess Grace Hospital Centre, Boston Scientific (United States) et Cambridge Scientific (United States), avec 3 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.