Aller au contenu principal
2024 article

Accuracy of Patient-Collected Vital Signs

3Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Introduction: Telehealth has emerged as an important clinical setting for managing acute respiratory tract infections (ARIs), potentially reducing emergency department and urgent care overcrowding, and reducing nosocomial transmission. Many current algorithms for ARI management incorporate information on patient vital signs. However, the accuracy of vital signs collected by patients using readily available home devices and techniques has not been studied. Methods: A cross-sectional sample of patients seen for urgent conditions at a hospital emergency and urgent care center were given instructions and low-cost, readily available devices to collect their vital signs. A trained research coordinator collected a parallel set of vital signs using standard hospital equipment, serving as the gold standard. We analyzed the performance of patient-collected vital signs compared with vital signs collected by a trained research coordinator. Results: A total of 300 patients completed the study. Patient-collected vital signs were highly specific for traditional levels of abnormalities (HR >100 beats per min, RR >24 breaths per min, temperature >100.4 degrees Fahrenheit, oxygen saturation <94 percent); however, sensitivity was poor for elevated heart rate by pulse estimation (25%) and elevated respiratory rate (60%). Heart rate and oxygen saturation by pulse oximeter and oral temperature had higher sensitivity. Conclusions: Vital signs measured and provided by patients are not uniformly accurate, particularly when using manual techniques rather than automated devices. Telehealth algorithms that rely on these values could provide incorrect triage and management advice.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Accuracy of Patient-Collected Vital Signs
Date Crossref
16/08/2024
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Emergency and Acute Care StudiesClinical Reasoning and Diagnostic SkillsMedical Malpractice and Liability Issues

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.