Aller au contenu principal
2024 article

Evaluation of radiation dose to the lens in interventional cardiology physicians before and after dose limit regulation changes

18Citations signalées — pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Abstract In response to the International Commission on Radiological Protection, which lowered the lens equivalent dose limit, Japan lowered the lens dose limit from 150 mSv y−1 to 100 mSv/5 years and 50 mSv y−1, with this new rule taking effect on 1 April 2021. DOSIRIS® is a dosimeter that can accurately measure lens dose. Herein, we investigated lens dose in interventional cardiology physicians 1 year before and after the reduction of the lens dose limit using a neck dosimeter and lens dosimeter measurements. With an increase in the number of cases, both personal dose equivalent at 0.07 mm depth [Hp(0.07), neck dosimeter] and personal dose equivalent at 3 mm depth [Hp(3), lens dosimeter] increased for most of the physicians. The Hp(3) of the lens considering the shielding effect of the Pb glasses using lens dosimeter exceeded 20 mSv y−1 for two of the 14 physicians. Protection from radiation dose will become even more important in the future, as these two physicians may experience radiation dose exceeding 100 mSv/5 years. The average dose per procedure increased, but not significantly. There was a strong correlation between the neck dosimeter and lens dosimeter scores, although there was no significant change before and after the lens dose limit was lowered. This correlation was particularly strong for physicians who primarily treated patients. As such, it is possible to infer accurate lens doses from neck doses in physicians who primarily perform diagnostics. However, it is desirable to use a dosimeter that can directly measure Hp(3) because of the high lens dose.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Evaluation of radiation dose to the lens in interventional cardiology physicians before and after dose limit regulation changes
Date Crossref
01/09/2024
Éditeur
IOP Publishing
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Radiation Dose and ImagingRadiology practices and educationAdvanced X-ray and CT Imaging

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.