Aller au contenu principal
2024 article

Intracameral Enoxaparin for Descemet Membrane Endothelial Keratoplasty: A Pilot Safety Study

5Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PURPOSE: The purpose of this study was to investigate the safety and outcomes of Descemet membrane endothelial keratoplasty (DMEK) performed with intracameral enoxaparin. METHODS: Two arms were used: a clinical multicenter retrospective cohort arm (CA) and an ex vivo basic science arm (BSA). In CA, DMEKs were performed by 6 experienced corneal surgeons at multiple sites. Intracameral enoxaparin (40 mg/500 mL) was added to the irrigation fluid for all cases. Primary outcomes were measured at 6 and 12 months. In BSA, mated graft pairs were randomized to control or enoxaparin exposure (0.8 mg/mL × 1 hour) and assessed for endothelial cell death count at 0-, 1-, and 24-hour intervals and cellular stress by ELISA Annexin V protein quantification. RESULTS: In the cohort arm, the mean age of 159 eyes of 134 patients was 69.3 years with Fuchs dystrophy as the primary diagnosis. Mean BCVA improved from 0.42 ± 0.3 logMAR preoperatively to 0.13 ± 0.1 logMAR postoperatively at 6 months (P < 0.001) and to 0.1 ± 0.1 logMAR at 12 months (P < 0.001). At 6 months, 58.4% of patients achieved a final BCVA of 20/25 or better and 91% improved to 20/40 or better. Rebubble rate was 13% (n = 21), with 6 of these 21 eyes requiring more than 1 rebubble. One total graft detachment was noted with no reports of intraoperative or postoperative hemorrhage. PGF occurred in 0 of 159 eyes. In BSA, enoxaparin had no significant effect on endothelial cell death count or cellular apoptosis compared with control. CONCLUSIONS: Enoxaparin can safely be used in DMEK surgery without apparent increased risk of intraoperative hemorrhage, graft detachment/failure, or endothelial cell toxicity.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Intracameral Enoxaparin for Descemet Membrane Endothelial Keratoplasty: A Pilot Safety Study
Date Crossref
08/08/2024
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Corneal surgery and disordersRetinal and Macular SurgeryCorneal Surgery and Treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.