Aller au contenu principal
Accès ouvert déclaré 2024 article

High-Density and High-Coverage Composite Atrial Activation Maps: An In-Silico Validation Study

1Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
4Pays d’affiliation déclarés

Rattachement africain : nl, gb, it, ch. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVE: Repetitive atrial activation patterns (RAAPs) during complex atrial tachycardia could be associated with localized mechanisms that can be targeted. Clinically available electroanatomical mapping systems are limited by either the spatial coverage or electrode density of the mapping catheters, preventing the adequate visualization of transiently occurring RAAPs. This work proposes a technique to overcome this shortcoming by stitching spatially overlapping conduction patterns together to a larger image- called a composite map. METHODS: Simulated stable mechanisms and meandering reentries are sequentially mapped (4 × 4 grid, 3 mm spacing) and then reconstructed back to the original sizes with the proposed recurrence plot-based algorithm. RESULTS: The reconstruction of single linear waves presents minimal errors (local activation time (LAT) difference: 3.2 [1.6-4.9] ms, conduction direction difference: 5.2 [2.3-8.0] degrees). Errors significantly increase (p<0.05) for more complex patterns, being the highest with unstable reentries (LAT difference: 10.3 [3.5-16.2] ms, conduction direction difference: 18.2 [6.7-29.7] deg). In a second part of the analysis, 111 meandering reentries are reconstructed. Mapping 30 locations overlappingly around each reentry core was found to be the optimal mapping strategy. For this optimal setting, LAT, conduction direction, and core localization errors are low (6.1 [4.2-8.6] ms, 11.2 [8.6-15.5] deg and 4.1 [2.9-4.9] mm, respectively) and are weakly correlated with the degree of the meander ( = 0.41, = 0.40 and = 0.20, respectively). CONCLUSION: Our findings underline the feasibility of generating composite maps by stitching spatially overlapping recordings. SIGNIFICANCE: Composite maps can be instrumental in personalized ablation strategies.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
High-Density and High-Coverage Composite Atrial Activation Maps: An In-Silico Validation Study
Date Crossref
01/01/2025
Éditeur
Institute of Electrical and Electronics Engineers (IEEE)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Arrhythmias and TreatmentsAtrial Fibrillation Management and OutcomesCardiac electrophysiology and arrhythmias

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.