Aller au contenu principal
Accès ouvert déclaré 2024 article

Early Experience With the Iliac Branch Endoprosthesis (IBE) in Managing Iliac Aneurysms

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Aim The objective of this study is to evaluate the feasibility of using iliac branch endoprosthesis (IBE) devices and to examine their short-term outcomes. Materials and methods This was a descriptive, retrospective observational study involving 15 patients diagnosed with either aortoiliac or isolated iliac artery aneurysms and treated with an IBE device. Data were collected for patients who received IBE devices at Glan Clwyd Hospital in Rhyl, United Kingdom, from February 2020 to May 2023. Results Most patients presented with asymptomatic aneurysms; 86.7% (n = 13) had bilateral common iliac artery (CIA) aneurysms. The mean diameter of the CIA was 38.7 ± 8.8 mm, and the mean diameter of the abdominal aortic aneurysm (AAA) was 39.8 ± 23 mm. For the indications of IBE use, 60% (n = 9) of the patients had iliac aneurysms reaching the intervention threshold, 20% (n = 3) had AAA reaching the threshold, and 20% (n = 3) had aortoiliac aneurysms reaching the threshold. The majority of patients underwent bilateral femoral access (86.7%; n = 13), while 13.3% (n = 2) required both femoral and brachial access. Technical success was achieved in all cases. Aside from 20% (n = 3) of cases where the sac size remained static, the majority of patients (80%; n = 12) experienced sac regression. All patients were free from buttock claudication. A type II endoleak was observed in 33.3% (n = 5) of patients. No reinterventions were reported. The mean primary patency was 30.9 ± 0.7 months, and the follow-up period ranged from 12 to 36 months. Conclusions IBEs are an effective medical device, demonstrating a high rate of technical success, minimal need for additional procedures, and a low incidence of complications while maintaining a satisfactory rate of primary patency.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Early Experience With the Iliac Branch Endoprosthesis (IBE) in Managing Iliac Aneurysms
Date Crossref
01/08/2024
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Aortic aneurysm repair treatmentsVascular Procedures and ComplicationsInfectious Aortic and Vascular Conditions

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.