Aller au contenu principal
Accès ouvert déclaré 2024 article

A Patch Wearable Cardioverter-Defibrillator for Patients at Risk of Sudden Cardiac Arrest

8Citations signalées, ce qui n’est pas une note de qualité
17Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: For many patients, sudden cardiac arrest (SCA) risk is elevated temporarily. Wearable cardioverter-defibrillators (WCDs) can monitor and treat SCA during these temporary periods. Traditional WCDs can be uncomfortable, require frequent maintenance, and cannot be used when showering, resulting in poor compliance and avoidable SCA deaths. The Jewel is a novel, water-resistant patch-wearable cardioverter-defibrillator (P-WCD) with a machine learning detection algorithm designed to improve compliance and protection against SCA. OBJECTIVES: This study aims to demonstrate the safety and clinical effectiveness of a novel P-WCD. METHODS: The Jewel IDE Study, a prospective, single-arm study conducted at 30 U.S. sites, enrolled patients at SCA risk due to ventricular tachycardia/ventricular fibrillation who were not candidates for or refused an implantable defibrillator. The primary safety endpoint was <15% patients with clinically significant cutaneous adverse device effects and the primary effectiveness endpoint was <2 inappropriate shocks/100 patient-months. Secondary endpoints were ≥1 successful ventricular tachycardia/ventricular fibrillation conversion and wear time compliance of >14.1 h/d. RESULTS: A total of 305 patients (mean age: 57.9 years; 30.2% female, 27.9% non-White) were enrolled, of which 290 had available device data. The clinically significant cutaneous adverse device effect rate was 2.30% (upper 1-sided 98% CI: 4.80); none were severe. No device-related deaths or serious adverse events were reported. The inappropriate shock rate was 0.36/100 patient-months (upper 1-sided 98% CI: 1.53). Of 11 shocks in 9 patients, 9 shocks were adjudicated to be appropriate. Eight of 9 shocks were successful with a single shock. Median wear time compliance was 23.5 (20.7-23.9) h/d. CONCLUSIONS: The novel P-WCD is a safe and effective WCD with high patient compliance. There were no deaths due to noncompliance and a high number of successful conversions (Jewel IDE study [A Clinical Evaluation of the Jewel P-WCD in Subjects at High Risk for Sudden Cardiac Arrest]; NCT05201495).

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A Patch Wearable Cardioverter-Defibrillator for Patients at Risk of Sudden Cardiac Arrest
Date Crossref
01/08/2024
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Arrest and ResuscitationCardiac pacing and defibrillation studiesCardiac electrophysiology and arrhythmias

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.