A Prospective Evaluation of the Diagnostic Accuracy of the Point-of-Care VISITECT CD4 Advanced Disease Test in 7 Countries
Résumé fourni par la source
BACKGROUND: CD4 measurement is pivotal in the management of advanced human immunodeficiency virus (HIV) disease. VISITECT CD4 Advanced Disease (VISITECT; AccuBio, Ltd) is an instrument-free, point-of-care, semiquantitative test allowing visual identification of CD4 ≤ 200 cells/µL or >200 cells/ µL from finger-prick or venous blood. METHODS: As part of a diagnostic accuracy study of FUJIFILM SILVAMP TB LAM, people with HIV ≥18 years old were prospectively recruited in 7 countries from outpatient departments if a tuberculosis symptom was present, and from inpatient departments. Participants provided venous blood for CD4 measurement using flow cytometry (reference standard) and finger-prick blood for VISITECT (index text), performed at point-of-care. Sensitivity, specificity, and positive and negative predictive values of VISITECT to determine CD4 ≤ 200 cells/ µL were evaluated. RESULTS: Among 1604 participants, the median flow cytometry CD4 was 367 cells/µL (interquartile range, 128-626 cells/µL) and 521 (32.5%) had CD4 ≤ 200 cells/µL. VISITECT sensitivity was 92.7% (483/521; 95% confidence interval [CI], 90.1%-94.7%) and specificity was 61.4% (665/1083; 95% CI, 58.4%-64.3%). For participants with CD4 0-100, 101-200, 201-300, 301-500, and >500 cells/µL, VISITECT misclassified 4.5% (95% CI, 2.5%-7.2%), 12.5 (95% CI, 8.0%-18.2%), 74.1% (95% CI, 67.0%-80.5%), 48.0% (95% CI, 42.5%-53.6%), and 22.6% (95% CI, 19.3%-26.3%), respectively. CONCLUSIONS: VISITECT's sensitivity, but not specificity, met the World Health Organization's minimal sensitivity and specificity threshold of 80% for point-of-care CD4 tests. VISITECT's quality needs to be assessed and its accuracy optimized. VISITECT's utility as CD4 triage test should be investigated. Clinical Trials Registration. NCT04089423.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- A Prospective Evaluation of the Diagnostic Accuracy of the Point-of-Care VISITECT CD4 Advanced Disease Test in 7 Countries
- Date Crossref
- 24/07/2024
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.