Aller au contenu principal
Accès ouvert déclaré 2024 article

Renal Function Preservation in Purely Off-Clamp Sutureless Robotic Partial Nephrectomy: Initial Experience and Technique

10Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The aim of our study is to evaluate the effectiveness and safety of a sutureless off-clamp robot-assisted partial nephrectomy (sl-oc RAPN), particularly its impact on renal function. A multicenter study was conducted from April 2021 to June 2022. Patients diagnosed with a renal mass of >2 cm and a PADUA score of ≤6 consecutively underwent an sl-oc RAPN procedure. Tumor features, patients characteristics, and intraoperative outcomes were assessed. An evaluation of renal function was performed preoperatively, and again at 1 and 3 months after surgery by measuring the creatinine and blood urea nitrogen levels. The renal function of the two separate kidneys was assessed by a sequential renal scintigraphy performed before and at least 30 days after surgery. A total of 21 patients underwent an sl-oc RAPN. The median age was 64 years (IQR 52/70), the median tumor diameter was 40 mm (IQR 29/45), and the median PADUA score was 4 (3.5/5). The intraoperative outcomes included operative time (OT), 90 (IQR 74/100) min; estimated blood loss (EBL), 150 (IQR 50/300) mL; and perioperative complications, CD > 3 1(5%); only two patients presented positive surgical margins in their final histology (2/21, 10%). Compared to the preoperative value, a decrease in renal function was highlighted with a statistically significant median decrease of 10 mL/min (p < 0.01). The renal scintigraphy showed an overall decrease in renal function compared to the preoperative value, with a range in the operated kidney that varied from 0 to 15 mL/s and from 0% to 40%, with a median value of 4 mL/s and 12%. sl-oc RAPN is a safe procedure, with a minimal impact on kidney function alteration. This technique has proven effective in preserving renal function and maintaining optimal oncological outcomes with limited complications.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Renal Function Preservation in Purely Off-Clamp Sutureless Robotic Partial Nephrectomy: Initial Experience and Technique
Date Crossref
23/07/2024
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Renal cell carcinoma treatmentRenal and Vascular PathologiesPediatric Urology and Nephrology Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.