Normothermic regional perfusion in controlled DCD liver procurement: Outcomes of the Swedish national implementation protocol
Rattachement africain : se. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Liver transplantation (LTX) using donors after controlled circulatory death (cDCD) is associated with poorer graft survival and increased incidence of nonanastomotic biliary strictures (NASs) compared to livers procured from brain-dead donors (DBD). The use of normothermic regional perfusion (NRP) during cDCD procurement may improve posttransplant outcomes and reduce the incidence of NAS. In Sweden, cDCD LTX was introduced through a national pilot protocol with mandatory NRP. This study aims to evaluate the outcome of cDCD LTX during the pilot period. Donor and recipient data were collected on all cDCD liver transplants during the pilot period between January 2020 to December 2022. Outcome on NAS, patient and graft survival, early allograft dysfunction, acute kidney injury, and comprehensive complication index was compared to a matched cohort of 28 patients transplanted with a DBD liver between 2018 and 2022. Eighteen patients were transplanted with a liver from a cDCD donor after using NRP. The mean functional warm ischemia time was 29 ± 6 minutes. The mean lactate reduction during NRP was 8.7 ± 2.4 mmol/L, and the end NRP perfusate alanine aminotransferase was 1.4 ± 1 µkat/L. When comparing recipients of cDCD liver transplant to DBD, no significant differences were observed in the incidence of NAS, patient and graft survival, comprehensive complication index, early allograft dysfunction, or acute kidney injury. Study protocol magnetic resonance cholangiopancreatography in cDCD patients showed no signs of subclinical biliary strictures. Evaluation of the Swedish national pilot of cDCD LTX with mandatory NRP shows comparable outcomes to a matched DBD cohort with 94.4% 1-year patient and graft survival and no incidence of NAS within the first year.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Normothermic regional perfusion in controlled DCD liver procurement: Outcomes of the Swedish national implementation protocol
- Date Crossref
- 23/07/2024
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Karolinska University Hospital Department of Transplantation Surgery pays non établi dans la noticeÉtablissement de santé
-
Karolinska Institutet Department of Medicine pays non établi dans la noticeUniversité ou école supérieure
-
Sahlgrenska University Hospital Transplant Institute pays non établi dans la noticeÉtablissement de santé
-
Stockholm South General Hospital pays non établi dans la noticeÉtablissement de santé
-
Department of Clinical Science pays non établi dans la noticeÉtablissement de santé
Department of Transplantation Surgery — Karolinska University Hospital, Department of Medicine — Karolinska Institutet et Transplant Institute — Sahlgrenska University Hospital, avec 2 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.