Aller au contenu principal
Accès ouvert déclaré 2024 article

Efficiency of Long Lateral Mass Screw in Posterior Cervical Fusion

1Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

INTRODUCTION: Long lateral mass screw (LLMS) technique for posterior cervical fusion has been performed in our hospital since 2019. In this study, the LLMS insertion technique, deviation rate, and insertion torque have been described. Moreover, several major concerns associated with LLMS have been adequately addressed. METHODS: This study included 58 patients (43 men and 15 women) who had undergone LLMS surgery at our hospital during the four-year period from December 2019 to December 2023, and were evaluated using postoperative CT. The evaluation parameters included the screw length at each vertebral segment, screw angle in the sagittal section, distance between the screw heads, and complications. RESULTS: The median screw length at C3 was 23.0 mm (22.0-24.0 mm), the screw angle was 36.1° (31.6-41.8°), and the distance between screw heads was 13.8 mm (11.6-17.2 mm). The median screw length at C4 was 22.0 mm (21.0-24.0 mm), the screw angle was 36.2° (28.7-40.7°), and the distance between screw heads was 15.9 mm (13.0-19.0 mm). The median screw length at C5 was 21.0 mm (20.0-22.0 mm), the screw angle was 35.6° (28.0-39.7°), and the distance between screw heads was 17.6 mm (15.1-20.4 mm). The median screw length for C6 was 20.0 mm (19.0-22.0 mm), the screw angle was 29.2° (25.2-36.8°), and the distance between screw heads was 20.4 mm (16.1-24.4 mm). CONCLUSION: The major limitations of the LLMS technique were inadequate screw angle, difficulty inserting long screws, inadequate decompression, and the inability to perform cervical laminoplasty. However, these limitations did not substantially affect the efficiency of LLMS. LLMS has fewer complications and can insert longer screws than LMS.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Efficiency of Long Lateral Mass Screw in Posterior Cervical Fusion
Date Crossref
22/07/2024
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Kawasaki Medical School pays non établi dans la notice
    Université ou école supérieure
  • Orthopaedics pays non établi dans la notice
    Institution

Kawasaki Medical School et Orthopaedics.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Spinal Fractures and Fixation TechniquesCervical and Thoracic MyelopathyScoliosis diagnosis and treatment

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.