Exploring the impact of excluding intrahepatic segmental vessels on liver stiffness measurement and advanced fibrosis diagnosis using magnetic resonance elastography
Rattachement africain : kr. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background The impact of excluding intrahepatic segmental vessels from regions of interest (ROIs) on liver stiffness measurement (LSM) via magnetic resonance elastography (MRE) remains uncertain. Purpose To determine the effect of excluding intrahepatic segmental vessels from ROIs on LSM obtained from MRE. Material and Methods This retrospective analysis included 95 participants who underwent successful two-dimensional gradient recalled-echo MRE before hepatic tumor resection (n = 49) or living liver donation (n = 46). The conventional LSM was determined by manually drawing ROIs on the elastogram within the 95% confidence region, staying 1 cm within the liver capsule and excluding large hilar vessels, the gallbladder, hepatic lesions, and artifacts. In addition, the modified LSM was determined by excluding intrahepatic segmental vessels. LSMs obtained by the two methods were compared with paired sample signed-rank test. Diagnostic performance for advanced fibrosis was calculated and compared using McNemar's test and Delong's test. The stage of hepatic fibrosis was assessed using surgical specimens by the METAVIR system. Results The modified LSM was larger than the conventional LSM (2.4 kPa vs. 2.2 kPa in reader 1; 2.7 kPa vs. 2.4 kPa in reader 2; P < 0.001). The modified LSM showed superior sensitivity (0.841 vs. 0.659 in reader 1; 0.864 vs. 0.705 in reader 2; P < 0.05) and area under the curve (0.901 vs. 0.820 in reader 1; 0.912 vs. 0.843 in reader 2; P < 0.05) for detecting advanced fibrosis (≥F3) than conventional LSM. Conclusion The exclusion of intrahepatic segmental vessels from ROIs in MRE affected the LSM and enhanced diagnostic performance for advanced fibrosis.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Exploring the impact of excluding intrahepatic segmental vessels on liver stiffness measurement and advanced fibrosis diagnosis using magnetic resonance elastography
- Date Crossref
- 21/07/2024
- Éditeur
- SAGE Publications
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.